Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Computer Aided Intracranial Aneurysm Treatment Based on 2D/3D Mapping, Virtual Deployment and Online Distal Marker Detection

Dazeo, Nicolás IgnacioIcon ; Orlando, José IgnacioIcon ; García, CamilaIcon ; Muñoz, Romina LucianaIcon ; Obrado, Laura; Fernandez, Hector; Blasco, Jordi; San Román, Luis; Macho, Juan M.; Ding, Andreas; Utz, Raphael; Larrabide, IgnacioIcon
Fecha de publicación: 08/2024
Editorial: Springer
Revista: Cardiovascular Engineering and Technology
ISSN: 1869-408X
e-ISSN: 1869-4098
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Ciencias de la Computación

Resumen

Purpose: To introduce a computational tool for peri-interventional intracranial aneurysm treatment guidance that maps preoperative planning information from simulation onto real-time X-Ray imaging. Methods: Preoperatively, multiple flow diverter (FD) devices are simulated based on the 3D mesh of the vessel to treat, to choose the optimal size and location. In the peri-operative stage, this 3D information is aligned and mapped to the continuous 2D-X-Ray scan feed from the operating room. The current flow diverter position in the 3D model is estimated by automatically detecting the distal FD marker locations and mapping them to the treated vessel. This allows to visually assess the possible outcome of releasing the device at the current position, and compare it with the one chosen pre-operatively. Results: The full pipeline was validated using retrospectively collected biplane images from four different patients (5 3D-DSA datasets in total). The distal FD marker detector obtained an average F1-score of 0.67 (+- 0.224) in 412 2D-X-Ray scans. After aligning 3D-DSA + 2D-X-Ray datasets, the average difference between simulated and deployed positions was 0.832 mm (+- 0.521 mm). Finally, we qualitatively show that the proposed approach is able to display the current location of the FD compared to their pre-operatively planned position. Conclusions: The proposed method allows to support the FD deployment procedure by merging and presenting preoperative simulation information to the interventionists, aiding them to make more accurate and less risky decisions.
Palabras clave: Cerebral aneurysm , Treatment guidance , Alignment , 3D-DSA
Ver el registro completo
 
Archivos asociados
Tamaño: 1.826Mb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/243746
URL: https://link.springer.com/10.1007/s13239-024-00745-y
DOI: http://dx.doi.org/10.1007/s13239-024-00745-y
Colecciones
Articulos(CCT - TANDIL)
Articulos de CTRO CIENTIFICO TECNOLOGICO CONICET - TANDIL
Citación
Dazeo, Nicolás Ignacio; Orlando, José Ignacio; García, Camila; Muñoz, Romina Luciana; Obrado, Laura; et al.; Computer Aided Intracranial Aneurysm Treatment Based on 2D/3D Mapping, Virtual Deployment and Online Distal Marker Detection; Springer; Cardiovascular Engineering and Technology; 8-2024; 1-13
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES