Mostrar el registro sencillo del ítem
dc.contributor.author
Marino Repizo, Leonardo

dc.contributor.author
Martinez, Luis Dante

dc.contributor.author
Olsina, Roberto Antonio

dc.contributor.author
Cerutti, Estela Soledad

dc.contributor.author
Raba, Julio

dc.date.available
2024-09-06T16:09:01Z
dc.date.issued
2011-11
dc.identifier.citation
Marino Repizo, Leonardo; Martinez, Luis Dante; Olsina, Roberto Antonio; Cerutti, Estela Soledad; Raba, Julio; A novel and rapid method for determination of natamycin in wines based on ultrahigh-performance liquid chromatography coupled to tandem mass spectrometry: validation according to the 2002/657/EC European decision; Springer Heidelberg; Analytical and Bioanalytical Chemistry; 402; 2; 11-2011; 965-973
dc.identifier.issn
1618-2642
dc.identifier.uri
http://hdl.handle.net/11336/243718
dc.description.abstract
A novel, simple, and rapid reversed-phase liquid chromatography–tandem mass spectrometric methodology was developed for the analysis of natamycin in wine samples. Natamycin was protonated to form singly charged ions in an electrospray positive ion mode. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring (MRM) of three fragment ion transitions (666.3→648.2, 666.3→503.3, and 666.3→485.2) to provide a high degree of sensitivity and specificity. Chromatographic separation was performed on a rapid resolution column using a mobile phase consisting of an acetonitrile/ water mixture with a total run time of 5.0 min. After only filtration as pretreatment, the sample was injected into the chromatographic system. The proposed method was validated in terms of selectivity, trueness, precision, decision limit (CCα), and detection capability (CCβ) according to 2002/657/EC Commission decision. The values for trueness, reported as bias (%), agreed with those established by the aforementioned document. Repeatability (intraday variability) values were 12.37% at a concentration of 1.0 μg L−1 and 8.99–4.19% at concentrations between 2.5 and 10 μg L−1 . The overall within-laboratory (interday variability) reproducibility was 15.47% at a concentration of 1.0 μg L−1 , which was significantly lower than the indicative value reported in the EU decision. The results indicated that the proposed approach is a sensitive, fast, reproducible, and robust methodology suitable for the analysis of natamycin levels in wine samples.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Springer Heidelberg

dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
NATAMYCIN
dc.subject
CHROMATOGRAPHY
dc.subject
TANDEM MASS
dc.subject.classification
Química Analítica

dc.subject.classification
Ciencias Químicas

dc.subject.classification
CIENCIAS NATURALES Y EXACTAS

dc.title
A novel and rapid method for determination of natamycin in wines based on ultrahigh-performance liquid chromatography coupled to tandem mass spectrometry: validation according to the 2002/657/EC European decision
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2024-08-20T13:03:41Z
dc.journal.volume
402
dc.journal.number
2
dc.journal.pagination
965-973
dc.journal.pais
Alemania

dc.journal.ciudad
Heidelberg
dc.description.fil
Fil: Marino Repizo, Leonardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Olsina, Roberto Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Cerutti, Estela Soledad. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.journal.title
Analytical and Bioanalytical Chemistry

dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://link.springer.com/article/10.1007/s00216-011-5481-6
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s00216-011-5481-6
Archivos asociados