Mostrar el registro sencillo del ítem
dc.contributor.author
Spinelli, Enrique Mario
dc.contributor.author
Haberman, Marcelo Alejandro
dc.date.available
2024-09-02T10:44:31Z
dc.date.issued
2010-09
dc.identifier.citation
Spinelli, Enrique Mario; Haberman, Marcelo Alejandro; Insulating electrodes: a review on biopotential front-ends for dielectric skin-electrode interfaces; IOP Publishing; Physiological Measurement; 31; 10; 9-2010; 183-198
dc.identifier.issn
0967-3334
dc.identifier.uri
http://hdl.handle.net/11336/243372
dc.description.abstract
Insulating electrodes, also known as capacitive electrodes, allow acquiring biopotentials without galvanic contact with the body. They operate with displacement currents instead of real charge currents, and the electrolytic electrode–skin interface is replaced by a dielectric film. The use of insulating electrodes is not the end of electrode interface problems but the beginning of new ones: coupling capacitances are of the order of pF calling for ultra-high input impedance amplifiers and careful biasing, guarding and shielding techniques. In this work, the general requirements of front ends for capacitive electrodes are presented and the different contributions to the overall noise are discussed and estimated. This analysis yields that noise bounds depend on features of the available devices as current and voltage noise, but the final noise level also depends on parasitic capacitances, requiring a careful shield and printed circuit design. When the dielectric layer is placed on the skin, the present-day amplifiers allow achieving noise levels similar to those provided by wet electrodes. Furthermore, capacitive electrodes technology allows acquiring high quality ECG signals through thin clothes. A prototype front end for capacitive electrodes was built and tested. ECG signals were acquired with these electrodes in direct contact with the skin and also through cotton clothes 350 μm thick. They were compared with simultaneously acquired signals by means of wet electrodes and no significant differences were observed between both output signals.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
IOP Publishing
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Insulating electrodes
dc.subject
active electrodes
dc.subject
non-contact measurements
dc.subject.classification
Otras Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información
dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Insulating electrodes: a review on biopotential front-ends for dielectric skin-electrode interfaces
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2024-08-21T13:02:45Z
dc.journal.volume
31
dc.journal.number
10
dc.journal.pagination
183-198
dc.journal.pais
Reino Unido
dc.description.fil
Fil: Spinelli, Enrique Mario. Universidad Nacional de La Plata. Facultad de Ingeniería. Departamento de Electrotecnia. Laboratorio de Electrónica Industrial, Control e Instrumentación; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
dc.description.fil
Fil: Haberman, Marcelo Alejandro. Universidad Nacional de La Plata. Facultad de Ingeniería. Departamento de Electrotecnia. Laboratorio de Electrónica Industrial, Control e Instrumentación; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
dc.journal.title
Physiological Measurement
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/0967-3334/31/10/S03
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org//10.1088/0967-3334/31/10/S03
Archivos asociados