Mostrar el registro sencillo del ítem

dc.contributor.author
Engelke, Wilfried  
dc.contributor.author
Müller, Alois  
dc.contributor.author
Decco, Oscar Alfredo  
dc.contributor.author
Rau, María J.  
dc.contributor.author
Cura, Andrea Cecilia  
dc.contributor.author
Ruscio, Mara L.  
dc.contributor.author
Knösel, Michael  
dc.date.available
2017-09-12T19:26:59Z  
dc.date.issued
2013-04  
dc.identifier.citation
Engelke, Wilfried; Müller, Alois; Decco, Oscar Alfredo; Rau, María J.; Cura, Andrea Cecilia; et al.; Displacement of dental implants in trabecular bone under a static lateral load in fresh bovine bone; Wiley; Clinical Implant Dentistry and Related Research; 15; 2; 4-2013; 160-165  
dc.identifier.issn
1523-0899  
dc.identifier.uri
http://hdl.handle.net/11336/24081  
dc.description.abstract
Aim: The study aims to provide objective data for the displacement of titanium screw implants in trabecular bone specimens. One hundred Semados implants (Bego, Bremen, Germany) were inserted in bovine type IV bone specimens. All implants had a diameter of 3.75 mm; 50 implants had a length of 8.5 mm and 50 implants had a length of 15 mm. Insertion torque was determined at intervals of 10, 20, and 30 Ncm. Implants were loaded horizontally with 10, 20, and 30 N for 2 seconds. An indicator strip was attached to the implant abutment to allow direct observation of implant movement relative to the bone surface. Horizontal displacement was assessed with an accuracy of measurement of 10 µm. Seven implants got lost by visible loosening. Degree of displacement was subject to evaluation with all others. Those implants showed a mean displacement of 59 µm for 10 N (n = 100), 173 µm for 20 N (n = 99), and 211 µm for 30 N (n = 93). The mean displacement of 15-mm implants (16, 37, 51 µm) was significantly lower compared with 8.5-mm implants (103, 311, 396 µm) corresponding to 10, 20, and 30 N as lateral loads. Conclusions: Displacement of screw implants in trabecular bone can be detected and visualized using commercially available endoscopes with a high magnification. A lateral load of 20 N indicates a mean displacement of over 100 µm and therefore results in a critical displacement.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Wiley  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Contact Endoscopy  
dc.subject
Displacement  
dc.subject
Implant Lenght  
dc.subject
Insertion Torque  
dc.subject
Lateral Loading  
dc.subject
Primary Stability  
dc.title
Displacement of dental implants in trabecular bone under a static lateral load in fresh bovine bone  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2017-09-12T16:30:20Z  
dc.identifier.eissn
1708-8208  
dc.journal.volume
15  
dc.journal.number
2  
dc.journal.pagination
160-165  
dc.journal.pais
Estados Unidos  
dc.journal.ciudad
Hoboken  
dc.description.fil
Fil: Engelke, Wilfried. Universität Göttingen; Alemania  
dc.description.fil
Fil: Müller, Alois. Private practice: dentist and oral surgeon; Alemania  
dc.description.fil
Fil: Decco, Oscar Alfredo. Universidad Nacional de Entre Rios. Facultad de Ingeniería. Departamento de Bioingeniería; Argentina  
dc.description.fil
Fil: Rau, María J.. Universidad Nacional de Entre Rios. Facultad de Ingeniería. Departamento de Bioingeniería; Argentina  
dc.description.fil
Fil: Cura, Andrea Cecilia. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Ruscio, Mara L.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina  
dc.description.fil
Fil: Knösel, Michael. Universität Göttingen; Alemania  
dc.journal.title
Clinical Implant Dentistry and Related Research  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://onlinelibrary.wiley.com/doi/10.1111/j.1708-8208.2011.00338.x/abstract  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1111/j.1708-8208.2011.00338.x