Mostrar el registro sencillo del ítem
dc.contributor.author
Engelke, Wilfried
dc.contributor.author
Müller, Alois
dc.contributor.author
Decco, Oscar Alfredo
dc.contributor.author
Rau, María J.
dc.contributor.author
Cura, Andrea Cecilia
dc.contributor.author
Ruscio, Mara L.
dc.contributor.author
Knösel, Michael
dc.date.available
2017-09-12T19:26:59Z
dc.date.issued
2013-04
dc.identifier.citation
Engelke, Wilfried; Müller, Alois; Decco, Oscar Alfredo; Rau, María J.; Cura, Andrea Cecilia; et al.; Displacement of dental implants in trabecular bone under a static lateral load in fresh bovine bone; Wiley; Clinical Implant Dentistry and Related Research; 15; 2; 4-2013; 160-165
dc.identifier.issn
1523-0899
dc.identifier.uri
http://hdl.handle.net/11336/24081
dc.description.abstract
Aim: The study aims to provide objective data for the displacement of titanium screw implants in trabecular bone specimens. One hundred Semados implants (Bego, Bremen, Germany) were inserted in bovine type IV bone specimens. All implants had a diameter of 3.75 mm; 50 implants had a length of 8.5 mm and 50 implants had a length of 15 mm. Insertion torque was determined at intervals of 10, 20, and 30 Ncm. Implants were loaded horizontally with 10, 20, and 30 N for 2 seconds. An indicator strip was attached to the implant abutment to allow direct observation of implant movement relative to the bone surface. Horizontal displacement was assessed with an accuracy of measurement of 10 µm. Seven implants got lost by visible loosening. Degree of displacement was subject to evaluation with all others. Those implants showed a mean displacement of 59 µm for 10 N (n = 100), 173 µm for 20 N (n = 99), and 211 µm for 30 N (n = 93). The mean displacement of 15-mm implants (16, 37, 51 µm) was significantly lower compared with 8.5-mm implants (103, 311, 396 µm) corresponding to 10, 20, and 30 N as lateral loads. Conclusions: Displacement of screw implants in trabecular bone can be detected and visualized using commercially available endoscopes with a high magnification. A lateral load of 20 N indicates a mean displacement of over 100 µm and therefore results in a critical displacement.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Wiley
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Contact Endoscopy
dc.subject
Displacement
dc.subject
Implant Lenght
dc.subject
Insertion Torque
dc.subject
Lateral Loading
dc.subject
Primary Stability
dc.title
Displacement of dental implants in trabecular bone under a static lateral load in fresh bovine bone
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2017-09-12T16:30:20Z
dc.identifier.eissn
1708-8208
dc.journal.volume
15
dc.journal.number
2
dc.journal.pagination
160-165
dc.journal.pais
Estados Unidos
dc.journal.ciudad
Hoboken
dc.description.fil
Fil: Engelke, Wilfried. Universität Göttingen; Alemania
dc.description.fil
Fil: Müller, Alois. Private practice: dentist and oral surgeon; Alemania
dc.description.fil
Fil: Decco, Oscar Alfredo. Universidad Nacional de Entre Rios. Facultad de Ingeniería. Departamento de Bioingeniería; Argentina
dc.description.fil
Fil: Rau, María J.. Universidad Nacional de Entre Rios. Facultad de Ingeniería. Departamento de Bioingeniería; Argentina
dc.description.fil
Fil: Cura, Andrea Cecilia. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Ruscio, Mara L.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
dc.description.fil
Fil: Knösel, Michael. Universität Göttingen; Alemania
dc.journal.title
Clinical Implant Dentistry and Related Research
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://onlinelibrary.wiley.com/doi/10.1111/j.1708-8208.2011.00338.x/abstract
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1111/j.1708-8208.2011.00338.x
Archivos asociados