Artículo
Role of recombinant Histoplasma capsulatum 100-kilodalton antigen in the diagnosis of histoplasmosis among HIV/AIDS patients: Antigenuria and antibodies detection
Toscanini, María Agustina
; Rodriguez Laboccetta, Carolina Mariel
; Videla Garrido, Agustin
; Posse, Gladys B.; Capece, Paula; Valdez, Ruth M.; Chacón, Yone A.; Gonzalez Maglio, Daniel Horacio
; Nusblat, Alejandro David
; Cuestas, María Luján
Fecha de publicación:
07/2023
Editorial:
Wiley Blackwell Publishing, Inc
Revista:
Mycoses
ISSN:
0933-7407
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
Background: Diagnosing progressive disseminated histoplasmosis (PDH) is still challenging in many countries where this disease is highly endemic. Definitive diagnosis is established by culture and/or by cytology/histopathology but both procedures have limited sensitivity and cultures are time-consuming. Antibodies detection by immunodiffusion has a low sensitivity in immunocompromised individuals. Commercially available antigen detection assays have high sensitivity in PDH cases; however, they are expensive and only performed in few laboratories. Aims: To describe the potential use of a novel ELISA for antibodies testing and a dot blot assay for antigen testing for diagnosing PDH using the recombinant 100 kDa protein of Histoplasma capsulatum (Hcp100) and their polyclonal antibodies as novel reagents, respectively. Methods: Serum and urine samples from a cohort of patients with HIV/AIDS and proven PDH were studied for the detection of anti-Hcp100 antibodies by ELISA and Hcp100 antigen by dot blot, respectively. Sensitivity, specificity and cross-reactions with other diseases were estimated for each assay and compared with those obtained using histoplasmin (HMN) as a reagent for antibodies detection by ELISA and immunodiffusion, and using a commercial antigenuria test. Results: Antibodies detection by the Hcp100 ELISA demonstrated 78.6% sensitivity and 88.4% specificity, versus 85.7% sensitivity and 81.0% specificity for the HMN ELISA and 26.1% sensitivity and 100% specificity for the immunodiffusion assay. Antigen detection by the Hcp100 dot blot demonstrated 89.3% sensitivity and 97.0% specificity versus 82.1% sensitivity and 90.9% specificity for the commercial test. Conclusion: The immunoassays described herein based on Hcp100 would be a valuable screening tool for diagnosing PDH.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(IDEHU)
Articulos de INST.DE EST.DE LA INMUNIDAD HUMORAL PROF.R.A.MARGNI
Articulos de INST.DE EST.DE LA INMUNIDAD HUMORAL PROF.R.A.MARGNI
Articulos(IMPAM)
Articulos de INSTITUTO DE INVESTIGACIONES EN MICROBIOLOGIA Y PARASITOLOGIA MEDICA
Articulos de INSTITUTO DE INVESTIGACIONES EN MICROBIOLOGIA Y PARASITOLOGIA MEDICA
Articulos(NANOBIOTEC)
Articulos de INSTITUTO DE NANOBIOTECNOLOGIA
Articulos de INSTITUTO DE NANOBIOTECNOLOGIA
Citación
Toscanini, María Agustina; Rodriguez Laboccetta, Carolina Mariel; Videla Garrido, Agustin; Posse, Gladys B.; Capece, Paula; et al.; Role of recombinant Histoplasma capsulatum 100-kilodalton antigen in the diagnosis of histoplasmosis among HIV/AIDS patients: Antigenuria and antibodies detection; Wiley Blackwell Publishing, Inc; Mycoses; 66; 7; 7-2023; 609-620
Compartir
Altmétricas