dc.description.abstract
We extend the diffusion tensor (DT) signal model for multiple-coil acquisition systems. Considering the sum-of-squares reconstruction method, we compute the Cramér–Rao bound (CRB) assuming the widely accepted noncentral chi distribution. Within this framework, we assess the effect of noise in DT estimation and other measures derived from it, as a function of the number of acquisition coils, as well as other system parameters. We show the applications of CRB in many actual problems related to DT estimation: we compare different gradient field setup schemes proposed in the literature and show how the CRB can be used to choose a convenient one; we show that for fiber-type anisotropy tensors the ellipsoidal area ratio (EAR) can be estimated with less error than other scalar factors such as the fractional anisotropy (FA) or the relative anisotropy (RA), and that for this type of anisotropy tensors, increasing the number of coils is equivalent to increasing the signal-to-noise ratio, i.e., the information of the different coils can be regarded as independent. Also, we present results showing the CRB of several parameters for actual DT-MRI data. We conclude that the CRB is a valuable tool to optimal experiment design in DT-related studies.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science Inc  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Cramér-Rao Bound  
dc.subject
Noncentral Chi Distribution  
dc.subject
Measurement Noise  
dc.subject.classification
Ingeniería de Sistemas y Comunicaciones  
dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Error bounds in diffusion tensor estimation using multiple-coil acquisition systems  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2017-08-23T20:35:16Z  
dc.journal.volume
31  
dc.journal.number
8  
dc.journal.pagination
1372-1383  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Beltrachini, Leandro. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de la Plata. Facultad de Ingeniería. Departamento de Electrotecnia. Laboratorio de Electrónica Industrial, Control e Instrumentación; Argentina  
dc.description.fil
Fil: Von Ellenrieder, Nicolás. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de la Plata. Facultad de Ingeniería. Departamento de Electrotecnia. Laboratorio de Electrónica Industrial, Control e Instrumentación; Argentina  
dc.description.fil
Fil: Muravchik, Carlos Horacio. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de la Plata. Facultad de Ingeniería. Departamento de Electrotecnia. Laboratorio de Electrónica Industrial, Control e Instrumentación; Argentina  
dc.journal.title
Magnetic Resonance Imaging  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.mri.2013.04.009  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0730725X13001653