Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

A robust method for the determination of lead in water samples using flow injection hydride generation atomic absorption spectrometry

Schlotthauer, JonatanIcon ; Mántaras, Leyla; Brusa, LucilaIcon ; Sigrist, Mirna Edit
Fecha de publicación: 02/2024
Editorial: Pergamon-Elsevier Science Ltd
Revista: Spectrochimica Acta Part B: Atomic Spectroscopy
ISSN: 0584-8547
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Química Analítica

Resumen

Flow injection hydride generation atomic absorption spectrometry (FI-HGAAS) is a sensitive technique for the quantification of trace amounts of lead. However, plumbane generation is not straightforward and usually HG methods for lead are not robust enough for routine analysis. The optimum pH range for Pb HG is very narrow, so strict control of the acidity of the reaction medium is required for reliable results and in some cases even acid concentrations used for sample preservation can interfere. Moreover, some elements, like Cu, can interfere in the HG reaction suppressing the Pb signal. In this paper we report the development and validation of a method for the determination of Pb in water samples that is robust towards acidity and Cu levels usually found in water samples. All hydride generation parameters were optimized, but special emphasis was put on robustness. The use of borate as a buffer significantly improved the robustness of the method towards acidity, compared to the typical non-buffered HG. Furthermore, the interference of Cu, Sb and Sn in the HG reaction was overcome using thiocyanate as a masking agent. Other elements do not interfere at levels typically found in water samples. The limit of quantification achieved (0.9 μg L− 1 ) is below the current guideline value for Pb in drinking water (10 μg L− 1 ). The linearity of the method was verified between the LOQ and up to 15 μg L− 1 . An analytical frequency of 25 samples per hour with 3 measurement replicates each was achieved. The method was applied to the analysis of 50 water samples. The concentrations found ranged from
Palabras clave: ATOMIC ABSORPTION SPECTROMETRY , FLOW INJECTION , HYDRIDE GENERATION , LEAD , PLUMBANE , WATER
Ver el registro completo
 
Archivos asociados
Tamaño: 685.0Kb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/231031
URL: https://www.sciencedirect.com/science/article/abs/pii/S0584854723002380
DOI: http://dx.doi.org/10.1016/j.sab.2023.106851
Colecciones
Articulos(CCT - SANTA FE)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - SANTA FE
Citación
Schlotthauer, Jonatan; Mántaras, Leyla; Brusa, Lucila; Sigrist, Mirna Edit; A robust method for the determination of lead in water samples using flow injection hydride generation atomic absorption spectrometry; Pergamon-Elsevier Science Ltd; Spectrochimica Acta Part B: Atomic Spectroscopy; 212; 2-2024; 1-7
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES