Mostrar el registro sencillo del ítem

dc.contributor.author
de Araújo Gomes, Adriano  
dc.contributor.author
Schenone, Agustina Violeta  
dc.contributor.author
Goicoechea, Hector Casimiro  
dc.contributor.author
Araújo, Mario Cesar  
dc.date.available
2017-08-25T21:39:46Z  
dc.date.issued
2015-05  
dc.identifier.citation
de Araújo Gomes, Adriano; Schenone, Agustina Violeta; Goicoechea, Hector Casimiro; Araújo, Mario Cesar; Unfolded partial least squares/residual bilinearizationcombined with the Successive Projections Algorithmfor interval selection:enhanced excitation-emission fluorescence data modeling in presence of inner filter effect; Springer Heidelberg; Analytical and Bioanalytical Chemistry; 407; 19; 5-2015; 5649-5659  
dc.identifier.issn
1618-2642  
dc.identifier.uri
http://hdl.handle.net/11336/23071  
dc.description.abstract
The use of the successive projections algorithm (SPA) for elimination of uninformative variables in interval selection, and unfold partial least squares regression (U-PLS) modeling of excitation-emission matrices (EEM),when under inner filter effect (IFE) is reported for first time. Post-calibration residual bilinearization (RBL) was employed against events of unknown components in the test samples. Inner filter effectcan originate changes in both the shape and intensity of analyte spectra, leading to trilinearity losses in both modes, and thus invalidating most multiway calibration methods. The algorithm presented in this paper was named iSPA-U-PLS/RBL. Both simulated and experimental data sets were used to compare the prediction capability during: a) simulated EEM; and b) quantitation of phenylephrine (PHE) in the presence of paracetamol (PAR) (or acetaminophen) in water samples. Test sets containing unexpected components were built in both systems (a single interference was taken into account in the simulated data set, while water samples were added with varying amounts of ibuprofen (IBU), and acetyl salicylic acid (ASA)). The prediction results and figures of merit obtained with the new algorithm were compared with those obtained with U-PLS/RBL (without intervals selection), and with the well-known parallel factors analysis (PARAFAC). In all cases, U-PLS/RBL displayedbetter EEM handling capability in the presence of inner filter effectas compared to PARAFAC. In addition, iSPA improved the results obtained with U-PLS/RBL, in this case demonstrating the potential of variable selection.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Springer Heidelberg  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Interval Selection  
dc.subject
Successive Projections Algorithm  
dc.subject
Unfolded-Partial Least Squares  
dc.subject
Second Order Calibration  
dc.subject
Inner Filter Effect  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Unfolded partial least squares/residual bilinearizationcombined with the Successive Projections Algorithmfor interval selection:enhanced excitation-emission fluorescence data modeling in presence of inner filter effect  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2017-08-17T13:43:55Z  
dc.journal.volume
407  
dc.journal.number
19  
dc.journal.pagination
5649-5659  
dc.journal.pais
Alemania  
dc.journal.ciudad
Heidelberg  
dc.description.fil
Fil: de Araújo Gomes, Adriano. Departamento de Química, Universidad Federal de Paraíba;  
dc.description.fil
Fil: Schenone, Agustina Violeta. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina  
dc.description.fil
Fil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas. Departamento de Química. Cátedra de Química Analítica; Argentina  
dc.description.fil
Fil: Araújo, Mario Cesar. Departamento de Química, Universidad Federal de Paraíba;  
dc.journal.title
Analytical and Bioanalytical Chemistry  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://link.springer.com/article/10.1007/s00216-015-8745-8  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s00216-015-8745-8