Mostrar el registro sencillo del ítem
dc.contributor.author
de Araújo Gomes, Adriano
dc.contributor.author
Schenone, Agustina Violeta
dc.contributor.author
Goicoechea, Hector Casimiro
dc.contributor.author
Araújo, Mario Cesar
dc.date.available
2017-08-25T21:39:46Z
dc.date.issued
2015-05
dc.identifier.citation
de Araújo Gomes, Adriano; Schenone, Agustina Violeta; Goicoechea, Hector Casimiro; Araújo, Mario Cesar; Unfolded partial least squares/residual bilinearizationcombined with the Successive Projections Algorithmfor interval selection:enhanced excitation-emission fluorescence data modeling in presence of inner filter effect; Springer Heidelberg; Analytical and Bioanalytical Chemistry; 407; 19; 5-2015; 5649-5659
dc.identifier.issn
1618-2642
dc.identifier.uri
http://hdl.handle.net/11336/23071
dc.description.abstract
The use of the successive projections algorithm (SPA) for elimination of uninformative variables in interval selection, and unfold partial least squares regression (U-PLS) modeling of excitation-emission matrices (EEM),when under inner filter effect (IFE) is reported for first time. Post-calibration residual bilinearization (RBL) was employed against events of unknown components in the test samples. Inner filter effectcan originate changes in both the shape and intensity of analyte spectra, leading to trilinearity losses in both modes, and thus invalidating most multiway calibration methods. The algorithm presented in this paper was named iSPA-U-PLS/RBL. Both simulated and experimental data sets were used to compare the prediction capability during: a) simulated EEM; and b) quantitation of phenylephrine (PHE) in the presence of paracetamol (PAR) (or acetaminophen) in water samples. Test sets containing unexpected components were built in both systems (a single interference was taken into account in the simulated data set, while water samples were added with varying amounts of ibuprofen (IBU), and acetyl salicylic acid (ASA)). The prediction results and figures of merit obtained with the new algorithm were compared with those obtained with U-PLS/RBL (without intervals selection), and with the well-known parallel factors analysis (PARAFAC). In all cases, U-PLS/RBL displayedbetter EEM handling capability in the presence of inner filter effectas compared to PARAFAC. In addition, iSPA improved the results obtained with U-PLS/RBL, in this case demonstrating the potential of variable selection.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Springer Heidelberg
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Interval Selection
dc.subject
Successive Projections Algorithm
dc.subject
Unfolded-Partial Least Squares
dc.subject
Second Order Calibration
dc.subject
Inner Filter Effect
dc.subject.classification
Otras Ciencias Químicas
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Unfolded partial least squares/residual bilinearizationcombined with the Successive Projections Algorithmfor interval selection:enhanced excitation-emission fluorescence data modeling in presence of inner filter effect
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2017-08-17T13:43:55Z
dc.journal.volume
407
dc.journal.number
19
dc.journal.pagination
5649-5659
dc.journal.pais
Alemania
dc.journal.ciudad
Heidelberg
dc.description.fil
Fil: de Araújo Gomes, Adriano. Departamento de Química, Universidad Federal de Paraíba;
dc.description.fil
Fil: Schenone, Agustina Violeta. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
dc.description.fil
Fil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas. Departamento de Química. Cátedra de Química Analítica; Argentina
dc.description.fil
Fil: Araújo, Mario Cesar. Departamento de Química, Universidad Federal de Paraíba;
dc.journal.title
Analytical and Bioanalytical Chemistry
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://link.springer.com/article/10.1007/s00216-015-8745-8
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s00216-015-8745-8
Archivos asociados