dc.description.abstract
This article studies the ocular behaviour of office workers in the presence of glare. Additionally, the study seeks to obtain a new indicator for glare prediction that compensates the inaccuracies of glare predicted by the existing models of glare sensation vote (GSV), daylight glare probability (DGP) and daylight glare index. A laboratory experiment was carried out (n=18) simulating an office space. The volunteers participated in four office tasks (reading from a screen and from a paper, writing and socializing). Two scenarios were evaluated: one with sunspots on the faces of the subjects and the other with sunspots on the working area. By means of a visible spectrum eye tracker these ocular parameters were registered: direction of gaze, the degree of opening of eye and pupil size. These ocular parameters were correlated with vertical illuminance at the eye. The results show that the degree of reduction of opening of the eye was the best predictor of visual discomfort with statistically significant differences between scenarios (p=?0.728, s =0.001). The other important predictor was the pupil size. The degree of opening of eye and pupil size was correlated with glare indices. The degree of eye opening has a good correlation with GSV and DGP and it could be a future index of visual comfort under situations of the risk of glare.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Sage Publications Ltd  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Visual Comfort  
dc.subject
Daylight Glare  
dc.subject
Visual Performance  
dc.subject
Ocular Indicator  
dc.subject
Glare Sensation Vote  
dc.subject
Daylight Glare Probability  
dc.subject
Daylight Glare Index  
dc.subject.classification
Ingeniería Oceanográfica  
dc.subject.classification
Ingeniería del Medio Ambiente  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Glare indicators: an analysis of ocular behaviour in an office equipped with venetian blinds  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2017-08-07T18:48:01Z  
dc.identifier.eissn
1423-0070  
dc.journal.volume
25  
dc.journal.pagination
69-80  
dc.journal.pais
Estados Unidos  
dc.journal.ciudad
California  
dc.description.fil
Fil: Yamin Garretón, Julieta Alejandra. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina  
dc.description.fil
Fil: Rodriguez, Roberto Germán. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina  
dc.description.fil
Fil: Pattini, Andrea Elvira. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina  
dc.journal.title
Indoor And Built Environment  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1177/1420326X14538082  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://journals.sagepub.com/doi/10.1177/1420326X14538082