Mostrar el registro sencillo del ítem

dc.contributor.author
Pacheco, Maria Emilia  
dc.contributor.author
Bruzzone, Liliana  
dc.date.available
2017-08-23T17:51:15Z  
dc.date.issued
2013-01  
dc.identifier.citation
Pacheco, Maria Emilia; Bruzzone, Liliana; Synchronous fluorescence spectrometry: Conformational investigation or inner filter effect?; Elsevier Science; Journal of Luminescence; 137; 1-2013; 138-142  
dc.identifier.issn
0022-2313  
dc.identifier.uri
http://hdl.handle.net/11336/22862  
dc.description.abstract
Synchronous fluorescence spectrometry has become a common tool to investigate conformational changes in proteins due to the presence of other molecules (quenchers). The same pattern is always followed, leaving aside the possibility of interfering effects that make conclusions incorrect. In this paper, we discuss the main cause of a wrong understanding of synchronous fluorescence spectrometry in a large number of papers published in many different journals. Based on the principles of synchronous fluorescence spectrometry, we perform a simple correction method of synchronous spectra taking into account inner filter effects. This criticism tries to demonstrate that the interpretation of synchronous fluorescence spectrometry is not as easy as it seems.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Synchronous Fluorescence Spectrometry  
dc.subject
Inner Filter Effect  
dc.subject
Bovine Serum Albumin  
dc.subject
Imazethapyr  
dc.subject
Chlorimuron-Ethyl  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Synchronous fluorescence spectrometry: Conformational investigation or inner filter effect?  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2017-08-22T14:06:14Z  
dc.journal.volume
137  
dc.journal.pagination
138-142  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Pacheco, Maria Emilia. Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Departamento de Quimica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Bruzzone, Liliana. Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Departamento de Quimica; Argentina  
dc.journal.title
Journal of Luminescence  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jlumin.2012.12.056  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0022231313000021