Mostrar el registro sencillo del ítem
dc.contributor.author
Contreras, Alejandro Ernesto
dc.contributor.author
Peirone, Alejandro R.
dc.contributor.author
Ledesma, Facundo
dc.contributor.author
Juaneda, Ernesto
dc.contributor.author
Defagó, Víctor
dc.contributor.author
Cuestas, Eduardo
dc.date.available
2024-02-23T11:23:08Z
dc.date.issued
2023-07
dc.identifier.citation
Contreras, Alejandro Ernesto; Peirone, Alejandro R.; Ledesma, Facundo; Juaneda, Ernesto; Defagó, Víctor; et al.; High-Sensitivity Cardiac Troponin T Variation After Percutaneous Atrial Septal Defect Closure; Texas Heart Inst; Texas Heart Institute Journal; 50; 4; 7-2023; 1-3
dc.identifier.issn
0730-2347
dc.identifier.uri
http://hdl.handle.net/11336/228144
dc.description.abstract
Troponin levels are used to rule in or rule out myocardial injury, with the T and I subunits being the biomarkers of choice. The use of high-sensitivity kits is recommended in clinical practice.1 There are no reference values after percutaneous occlusion of an ostium secundum–type atrial septal defect (ASD). The objective of this study was to describe the values of high-sensitivity cardiac troponin T (hs-cTnT) in a population that received percutaneous treatment for ASD without complications. This observational, prospective, and comparative study of repeated measurements was conducted between August 2020 and November 2022. Patients with ostium secundum–type ASD, dilated right heart chambers, and percutaneous closure of the defect with devices were consecutively included. High-sensitivity cardiac troponin T levels were measured before the intervention and at 6 hours after the end of the procedure. Measurements were performed on a Cobas autoanalyzer using an electrochemiluminescence assay (Roche). Ultrasensitive troponin T was used. The upper reference limit (URL) was 14 pg/mL. The protocol was approved by the Institutional Research Ethics Committee and Research Committee of the Hospital Privado Universitario de Córdoba. Patients and/or their guardians provided written informed consent.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Texas Heart Inst
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
CARDIAC CATHETERIZATION
dc.subject
HEART SEPTAL DEFECTS, ATRIAL
dc.subject
TROPONIN
dc.subject.classification
Pediatría
dc.subject.classification
Medicina Clínica
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
High-Sensitivity Cardiac Troponin T Variation After Percutaneous Atrial Septal Defect Closure
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2024-02-09T11:02:48Z
dc.journal.volume
50
dc.journal.number
4
dc.journal.pagination
1-3
dc.journal.pais
Estados Unidos
dc.description.fil
Fil: Contreras, Alejandro Ernesto. Hospital Privado Universitario de Córdoba; Argentina
dc.description.fil
Fil: Peirone, Alejandro R.. Hospital Privado Universitario de Córdoba; Argentina
dc.description.fil
Fil: Ledesma, Facundo. Hospital Privado Universitario de Córdoba; Argentina
dc.description.fil
Fil: Juaneda, Ernesto. Hospital Privado Universitario de Córdoba; Argentina
dc.description.fil
Fil: Defagó, Víctor. Hospital Privado Universitario de Córdoba; Argentina
dc.description.fil
Fil: Cuestas, Eduardo. Hospital Privado Universitario de Córdoba; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina
dc.journal.title
Texas Heart Institute Journal
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.14503/THIJ-23-8117
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://meridian.allenpress.com/thij/article/50/4/e238117/494684/High-Sensitivity-Cardiac-Troponin-T-Variation
Archivos asociados