Mostrar el registro sencillo del ítem
dc.contributor.author
Diaz, Alberto Alejandro
dc.contributor.author
Zócalo, Yanina
dc.contributor.author
Salazar, Federico
dc.contributor.author
Bia, Daniel
dc.date.available
2024-02-01T14:35:24Z
dc.date.issued
2023-05
dc.identifier.citation
Diaz, Alberto Alejandro; Zócalo, Yanina; Salazar, Federico; Bia, Daniel; Non-invasive central aortic pressure measurement: what limits its application in clinical practice?; Frontiers Media; Frontiers in Cardiovascular Medicine; 10; 5-2023; 1-5
dc.identifier.issn
2297-055X
dc.identifier.uri
http://hdl.handle.net/11336/225447
dc.description.abstract
The following article highlights the need for methodological transparency and consensus for an accurate and non-invasive assessment of central aortic blood pressure (aoBP), which would contribute to increasing its validity and value in both clinical and physiological research settings. The recording method and site, the mathematical model used to quantify aoBP, and mainly the method applied to calibrate pulse waveforms are essential when estimating aoBP and should be considered when analyzing and/or comparing data from different works, populations and/or obtained with different approaches. Up to now, many questions remain concerning the incremental predictive ability of aoBP over peripheral blood pressure and the possible role of aoBP-guided therapy in everyday practice. In this article, we focus on “putting it on the table” and discussing the main aspects analyzed in the literature as potential determinants of the lack of consensus on the non-invasive measurement of aoBP.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Frontiers Media
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
AORTIC BLOOD PRESSURE
dc.subject
BLOOD PRESSURE MEASUREMENT
dc.subject
CALIBRATION
dc.subject
CENTRAL BLOOD PRESSURE MEASUREMENT
dc.subject
NON-INVASIVE ASSESSMENT
dc.subject
OSCILLOMETRIC METHOD
dc.subject.classification
Sistemas Cardíaco y Cardiovascular
dc.subject.classification
Medicina Clínica
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
Non-invasive central aortic pressure measurement: what limits its application in clinical practice?
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2024-01-30T15:47:29Z
dc.journal.volume
10
dc.journal.pagination
1-5
dc.journal.pais
Suiza
dc.description.fil
Fil: Diaz, Alberto Alejandro. Universidad Nacional del Centro de la Provincia de Buenos Aires. Escuela Superior de Ciencias de la Salud. Instituto de Investigación en Ciencias de la Salud; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
dc.description.fil
Fil: Zócalo, Yanina. Universidad de la Republica. Facultad de Medicina; Uruguay
dc.description.fil
Fil: Salazar, Federico. Fundación Medica de Mar del Plata. Hospital Privado de Comunidad; Argentina
dc.description.fil
Fil: Bia, Daniel. Universidad de la Republica. Facultad de Medicina; Uruguay
dc.journal.title
Frontiers in Cardiovascular Medicine
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.frontiersin.org/articles/10.3389/fcvm.2023.1159433/full
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.3389/fcvm.2023.1159433
Archivos asociados