dc.description.abstract
The following article highlights the need for methodological transparency and consensus for an accurate and non-invasive assessment of central aortic blood pressure (aoBP), which would contribute to increasing its validity and value in both clinical and physiological research settings. The recording method and site, the mathematical model used to quantify aoBP, and mainly the method applied to calibrate pulse waveforms are essential when estimating aoBP and should be considered when analyzing and/or comparing data from different works, populations and/or obtained with different approaches. Up to now, many questions remain concerning the incremental predictive ability of aoBP over peripheral blood pressure and the possible role of aoBP-guided therapy in everyday practice. In this article, we focus on “putting it on the table” and discussing the main aspects analyzed in the literature as potential determinants of the lack of consensus on the non-invasive measurement of aoBP.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Frontiers Media  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
AORTIC BLOOD PRESSURE  
dc.subject
BLOOD PRESSURE MEASUREMENT  
dc.subject
CALIBRATION  
dc.subject
CENTRAL BLOOD PRESSURE MEASUREMENT  
dc.subject
NON-INVASIVE ASSESSMENT  
dc.subject
OSCILLOMETRIC METHOD  
dc.subject.classification
Sistemas Cardíaco y Cardiovascular  
dc.subject.classification
Medicina Clínica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Non-invasive central aortic pressure measurement: what limits its application in clinical practice?  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2024-01-30T15:47:29Z  
dc.journal.volume
10  
dc.journal.pagination
1-5  
dc.journal.pais
Suiza  
dc.description.fil
Fil: Diaz, Alberto Alejandro. Universidad Nacional del Centro de la Provincia de Buenos Aires. Escuela Superior de Ciencias de la Salud. Instituto de Investigación en Ciencias de la Salud; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina  
dc.description.fil
Fil: Zócalo, Yanina. Universidad de la Republica. Facultad de Medicina; Uruguay  
dc.description.fil
Fil: Salazar, Federico. Fundación Medica de Mar del Plata. Hospital Privado de Comunidad; Argentina  
dc.description.fil
Fil: Bia, Daniel. Universidad de la Republica. Facultad de Medicina; Uruguay  
dc.journal.title
Frontiers in Cardiovascular Medicine  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.frontiersin.org/articles/10.3389/fcvm.2023.1159433/full  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.3389/fcvm.2023.1159433