Mostrar el registro sencillo del ítem

dc.contributor.author
Karsenty, Clément  
dc.contributor.author
Alattar, Yousef  
dc.contributor.author
Mousseaux, Elie  
dc.contributor.author
Marcilhacy, Gabrielle  
dc.contributor.author
Gencer, Umit  
dc.contributor.author
Craiem, Damian  
dc.contributor.author
Iserin, Laurence  
dc.contributor.author
ladouceur, Magalie  
dc.contributor.author
Legendre, Antoine  
dc.contributor.author
Laredo, Mikael  
dc.contributor.author
Bonnet, Damien  
dc.contributor.author
Malekzadeh Milani, Sophie  
dc.contributor.author
Soulat, Gilles  
dc.date.available
2023-12-01T18:35:48Z  
dc.date.issued
2023-03  
dc.identifier.citation
Karsenty, Clément; Alattar, Yousef; Mousseaux, Elie; Marcilhacy, Gabrielle; Gencer, Umit; et al.; 4D flow magnetic resonance imaging to assess right ventricular outflow tract in patients undergoing transcatheter pulmonary valve replacement; Elsevier Doyma Sl; Revista Española de Cardiología; 76; 10; 3-2023; 793-802  
dc.identifier.issn
1885-5857  
dc.identifier.uri
http://hdl.handle.net/11336/219087  
dc.description.abstract
Introducción y objetivos La resonancia magnética (RM) con flujo 4D suele utilizarse para evaluar el ventrículo derecho y las arterias pulmonares antes del implante percutáneo de la válvula pulmonar (IPVP). Como el IPVP está limitado por el tamaño del tracto de salida del ventrículo derecho (TSVD), se necesita medirlo con precisión para planificar la intervención. El objetivo del presente estudio es comparar diferentes modalidades de RM con la medición invasiva del TSVD con balón. Métodos Estudio unicéntrico prospectivo de pacientes sometidos a IPVP por insuficiencia pulmonar aislada evaluada mediante RM con flujo 4D, precesión libre en estado estacionario/gradiente eco-3D (3D SSFP/GRE) y angiografía por RM con contraste. La medición con balón se consideró la referencia. Resultados Se incluyó a 23 adultos (media de edad, 38,4 ± 12,5 años). En 18 pacientes el IPVP fue exitoso. El diámetro medio del TSVD más pequeño fue de 25,4 ± 4,3 mm medido con balón y 25,6 ± 3,8 y 21,8 ± 3,6 mm por RM con flujo 4D en sístole y diástole respectivamente. Comparados con los medidos con balón, los diámetros del TSVD se correlacionaron mejor cuando se estimaron mediante RM con flujo 4D sistólico (r = 0,89; p < 0,001) que mediante RM con flujo 4D diastólico (r = 0,71; p < 0,001), angiografía por RM 3D con contraste (r = 0,73; p < 0,001) o 3D SSFP/GRE (r = 0,50; p = 0,04), y no se correlacionaron de manera significativa cuando se realizaron en 2D en diástole o sístole. La diferencia media entre la RM con flujo 4D sistólico y la medición con balón fue de 0,2 mm (IC95%, –3,5 a 3,9 mm), en tanto que con las otras técnicas fue mayor. Conclusiones Además de la cuantificación de la insuficiencia de la válvula pulmonar, la RM con flujo 4D permite una estimación fiable de los diámetros del TSVD, sobre todo en sístole, lo que es fundamental antes de planificar el IPVP.  
dc.description.abstract
Introduction and objectives: Magnetic resonance imaging (MRI) including 4D flow is used before percutaneous pulmonary valve implantation (PPVI). As PPVI is limited by the size of the right ventricular outflow tract (RVOT), accurate sizing is needed to plan the intervention. The aim of this study was to compare different MRI modalities and invasive angiography to balloon sizing of RVOT. Methods: Single-center prospective study of patients who underwent PPVI for isolated pulmonary regurgitation assessed by 4D flow MRI, 3D steady-state free precession/gradient echo (3D SSFP/GRE) and contrast magnetic resonance angiography. Balloon sizing was considered as the reference. Results: A total of 23 adults were included (mean age, 38.4+-12.5 years). Eighteen patients underwent successful primary PPVI. The average of the narrowest RVOT diameter was 25.4 +- 4.3 mm by balloon sizing.<br />Compared to balloon sizing, RVOT diameters were better correlated when estimated by systolic 4D flow MRI (r = 0.89, P < .001) than by diastolic 4D flow MRI (r = 0.71, P < .001), 3D contrast magnetic resonance angiography (r = 0.73; P < .001) and 3D SSFP/GRE (r = 0.50; P = .04) and was not significantly correlated when estimated by 2D in diastole and systole. The mean difference between systolic 4D flow MRI and balloon sizing was 0.2 mm (95%CI, –3.5 to 3.9 mm), whereas it was wider with other techniques. Conclusions: Beyond the quantification of pulmonary valve regurgitation, 4D flow allows accurate estimation of RVOT diameters, especially in systole, which is fundamental before planning PPVI.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Doyma Sl  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
MAGNETIC RESONANCE IMAGING  
dc.subject
TETRALOGY FALLOT  
dc.subject
PULMONARY VALVE  
dc.subject.classification
Ingeniería Médica  
dc.subject.classification
Ingeniería Médica  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
4D flow magnetic resonance imaging to assess right ventricular outflow tract in patients undergoing transcatheter pulmonary valve replacement  
dc.title
Evaluación del tracto de salida del ventrículo derecho mediante resonancia magnética con flujo 4D en pacientes sometidos a recambio valvular pulmonar transcatéter  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2023-11-28T15:04:34Z  
dc.journal.volume
76  
dc.journal.number
10  
dc.journal.pagination
793-802  
dc.journal.pais
España  
dc.journal.ciudad
Madrid  
dc.description.fil
Fil: Karsenty, Clément. Hopital Europeen Georges Pompidou; Francia. Children's Hospital; Francia. Institut National de la Santé et de la Recherche Médicale; Francia. Clinique Pasteur; Francia  
dc.description.fil
Fil: Alattar, Yousef. Hopital Europeen Georges Pompidou; Francia  
dc.description.fil
Fil: Mousseaux, Elie. Hopital Europeen Georges Pompidou; Francia. Institut National de la Santé et de la Recherche Médicale; Francia  
dc.description.fil
Fil: Marcilhacy, Gabrielle. Hopital Europeen Georges Pompidou; Francia  
dc.description.fil
Fil: Gencer, Umit. Institut National de la Santé et de la Recherche Médicale; Francia  
dc.description.fil
Fil: Craiem, Damian. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Medicina Traslacional, Trasplante y Bioingeniería. Fundación Favaloro. Instituto de Medicina Traslacional, Trasplante y Bioingeniería; Argentina  
dc.description.fil
Fil: Iserin, Laurence. Hopital Europeen Georges Pompidou; Francia  
dc.description.fil
Fil: ladouceur, Magalie. Hopital Europeen Georges Pompidou; Francia. Institut National de la Santé et de la Recherche Médicale; Francia  
dc.description.fil
Fil: Legendre, Antoine. Hopital Europeen Georges Pompidou; Francia  
dc.description.fil
Fil: Laredo, Mikael. Hopital Europeen Georges Pompidou; Francia. Assistance Publique Hôpitaux de Paris; Francia  
dc.description.fil
Fil: Bonnet, Damien. Universite de Paris; Francia. Hôpital Universitaire Necker-Enfants malades; Francia  
dc.description.fil
Fil: Malekzadeh Milani, Sophie. Hopital Europeen Georges Pompidou; Francia. Hôpital Universitaire Necker-Enfants malades; Francia  
dc.description.fil
Fil: Soulat, Gilles. Hopital Europeen Georges Pompidou; Francia. Institut National de la Santé et de la Recherche Médicale; Francia  
dc.journal.title
Revista Española de Cardiología  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S1885585723000725  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.rec.2023.02.010