Artículo

Horizontal and vertical fluxes of particulate matter during wind erosion on arable land in the province La Pampa, Argentina

Siegmund, Nicole ; Funk, Roger ; Sommer, Michael ; Avecilla, Fernando Icon; Panebianco, Juan Esteban Icon; Iturri, Laura Antonela Icon; Buschiazzo, Daniel Eduardo Icon

Otros responsables

Fecha

10/2022

Editorial

International Research and Training Centre on Erosion and Sedimentation

Revista

International Journal of Sediment Research

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1001-6279

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

A detailed analysis of horizontal and vertical particulate matter (PM) fluxes during wind erosion has been done, based on measurements of PM smaller than 10, 2.5, and 1.0 μm, at windward and leeward positions on a measuring field. The three fractions of PM measurement are differently influenced by the increasing wind and shear velocities of the wind. The measured concentrations of the coarser fractions of the fine dust, PM10, and PM2.5, increase with wind and shear velocity, whereas the PM1.0 concentrations show no clear correlation to the shear velocity. The share of PM2.5 on PM10 depends on the measurement height and wind speed and varies between 4 and 12 m/s at the 1 m height ranging from 25% to 7% (average 10%), and at the 4 m height from 39% to 23% (average 30%). Although general relationships between wind speed, PM concentration, and horizontal and vertical fluxes could be found, the contribution of the measuring field was very low, as balances of incoming and outgoing fluxes show. Consequently, the measured PM concentrations are determined from a variety of sources, such as traffic on unpaved roads, cattle drives, tillage operations, and wind erosion, and thus, represent all components of land use and landscape structure in the near and far surroundings of the measuring field. The current results may reflect factors from the landscape scale rather than the influence of field-related variables. The measuring devices used to monitor PM concentrations showed differences of up to 20%, which led to considerable deviations when determining total balances. Differences up to 67% between the calculated fluxes prove the necessity of a previous calibration of the devices used.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd