dc.description.abstract
Microwave-induced plasma optical emission spectrometry (MIP-OES) has been attracting growing interest since the introduction of a commercial instrument based on a Hammer cavity and resonant iris system (4100 MP-AES, Agilent Technologies) in 2012. During the past few years, important modifications have been made to the instrument to improve its analytical performance, and new models have been launched (4200 and 4210 MP-AES). These improvements, along with other performance studies, allowed for the instrument's use in several applications, with adequate analytical results, which raises the question of whether MIP-OES has positioned itself to become an alternative to the traditional inductively coupled plasma optical emission spectrometry (ICP-OES). In the present review, we describe recent advances in MIP-OES instrumentation and compare the method's figures of merit, as well as its ability to deal with matrix effects, with those typically observed in ICP-OES. We also discuss recent studies and strategies developed to overcome general MIP-OES limitations. Instrument accessories, plasma diagnostics strategies, new calibration methods, and developments in sample preparation and sample introduction are some of the strategies used to improve MIP-OES sensitivity and accuracy. Therefore, the aims of the present work are to identify applications for which MIP-OES has become competitive with ICP-OES, as well as to describe recent developments that contributed to MIP-OES' acceptance as a cost-effective alternative for trace element analysis.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Royal Society of Chemistry  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
MIPOES  
dc.subject
ICPOES  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Is MIP-OES a suitable alternative to ICP-OES for trace element analysis?  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2023-07-05T15:29:11Z  
dc.journal.pagination
1-19  
dc.journal.pais
Reino Unido  
dc.journal.ciudad
Cambridge  
dc.description.fil
Fil: Fontoura, Beatriz M.. Universidade Federal do São Carlos; Brasil  
dc.description.fil
Fil: Cora Jofré, Florencia. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina  
dc.description.fil
Fil: Williams, Trey. CLEMSON UNIVERSITY (CLEMSON UNIVERSITY);  
dc.description.fil
Fil: Savio, Marianela. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina  
dc.description.fil
Fil: Donati, George L.. University Wake Forest; Estados Unidos  
dc.description.fil
Fil: Nóbrega, Joaquim A.. Universidade Federal do São Carlos; Brasil  
dc.journal.title
Journal of Analytical Atomic Spectrometry  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://xlink.rsc.org/?DOI=D1JA00375E  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1039/D1JA00375E