Mostrar el registro sencillo del ítem
dc.contributor.author
Pérez Socas, Luis Benito
dc.contributor.author
Ambroggio, Ernesto Esteban
dc.date.available
2023-08-08T16:41:48Z
dc.date.issued
2022-02-23
dc.identifier.citation
Pérez Socas, Luis Benito; Ambroggio, Ernesto Esteban; Introducing the multi-dimensional spectral phasors: A tool for the analysis of fluorescence excitation-emission matrices; IOP Publishing Ltd; Methods and Applications in Fluorescence; 10; 2; 23-2-2022; 1-31
dc.identifier.uri
http://hdl.handle.net/11336/207446
dc.description.abstract
The use of phasors to analyze fluorescence data was first introduced for time-resolved studies for a simpler mathematical analysis of the fluorescence-decay curves. Recently, this approach was extended to steady-state experiments with the introduction of the spectral phasors (SP), derived from the Fourier transform of the fluorescence emission spectrum. In this work, we revise key mathematical aspects that lead to an interpretation of SP as the characteristic function of a probability distribution. This formalism allows us to introduce a new tool, called multi-dimensional spectral phasor (MdSP) that seize, not only the information from the emission spectrum, but from the full excitation-emission matrix (EEM). In addition, we developed a homemade open-source Java software to facilitate the MdSP data processing. Due to this mathematical conceptualization, we settled a mechanism for the use of MdSP as a tool to tackle spectral signal unmixing problems in a more accurate way than SP. As a proof of principle, with the use of MdSP we approach two important biophysical questions: protein conformational changes and protein-ligand interactions. Specifically, we experimentally measure the EEM changes upon denaturation of human serum albumin (HSA) or during its association with the fluorescence dye 1,8-anilinonaphtalene sulphate (ANS) detected via tryptophan-ANS Förster Resonance Energy Transfer (FRET). In this sense, MdSP allows us to obtain information of the system in a simpler and finer way than the traditional SP. Specifically, understanding a protein's EEM as a molecular fingerprint opens new doors for the use of MdSP as a tool to analyze and comprehend protein conformational changes and interactions.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
IOP Publishing Ltd
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
FLUORESCENCE EXCITATION-EMISSION MATRIX
dc.subject
FÖRSTER RESONANCE ENERGY TRANSFER
dc.subject
SIGNAL UNMIXING
dc.subject
SPECTRAL PHASOR
dc.subject.classification
Química Coloidal
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Introducing the multi-dimensional spectral phasors: A tool for the analysis of fluorescence excitation-emission matrices
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2023-07-07T21:33:47Z
dc.identifier.eissn
2050-6120
dc.journal.volume
10
dc.journal.number
2
dc.journal.pagination
1-31
dc.journal.pais
Reino Unido
dc.journal.ciudad
Londres
dc.description.fil
Fil: Pérez Socas, Luis Benito. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Centro de Investigaciones en Química Biológica de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Centro de Investigaciones en Química Biológica de Córdoba; Argentina
dc.description.fil
Fil: Ambroggio, Ernesto Esteban. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Centro de Investigaciones en Química Biológica de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Centro de Investigaciones en Química Biológica de Córdoba; Argentina
dc.journal.title
Methods and Applications in Fluorescence
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/2050-6120/ac5389
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1088/2050-6120/ac5389
Archivos asociados