Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Validation of an indirect in-house ELISA using synthetic peptides to detect antibodies anti-gp90 and gp45 of the equine infectious anaemia virus

Russi, Romina CeciliaIcon ; García, LucilaIcon ; Cámara, María Silvia; Soutullo, Adriana Rosa
Fecha de publicación: 01/2022
Editorial: Equine Veterinary Journal Ltd
Revista: Equine Veterinary Journal
ISSN: 0425-1644
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Enfermedades Infecciosas

Resumen

Background: Equine infectious anaemia (EIA) is controlled by the identification of seropositive animals. The official diagnostic method is the agar gel immunodiffusion (AGID) test, which detects antibodies against a viral core protein (p26). Although AGID is inexpensive and specific, the report of results takes considerable time and the test has low analytical sensitivity. Objective: To validate our in-house indirect ELISAgp90/45, following the World Organization of Animal Health (OIE) criteria. Study design: Test validation. Methods: Synthetic peptides gp90 and gp45 were used as antigens in ELISAgp90/45. Tests used for validation, calibration and linear working operating range, analytical and diagnostic sensitivity and specificity, repeatability and reproducibility were assessed by comparing them with the AGID test and using 1844 equine sera grouped into five different panels. Results: We were able to replace the National References Sera with our Internal Reference Sera. ELISAgp90/45 had acceptable repeatability and reproducibility. Analytical sensitivity of the ELISAgp90/45 was 800 times greater than that of AGID test for positive sera and 400 times greater for weak positive sera. ELISAgp90/45 also showed optimal analytical specificity, since no cross-reactivity was detected with antibodies against other equine viruses. One sample was positive by AGID test and negative by ELISAgp90/45. ELISAgp90/45 was performed using 243 EIA positive and 878 negative equid sera, and showed a diagnostic sensitivity of 99.59% [CI 97.73%-99.99%] and a diagnostic specificity of 90.32% [CI 88.17%-92.19%], compared to AGID test; thus, it was demonstrated to be a robust test. Main limitations: Samples were derived from naturally infected equid populations showing heterogeneous clinical states: therefore, their status was uncertain and some horses were sampled more than once. The AGID test may not be the most useful gold standard. Conclusion: ELISAgp90/45 is a useful tool for the diagnosis of EIAV infection and meets validation requirements established by the OIE.
Palabras clave: AGID TEST , ELISA , EQUINE INFECTIOUS ANAEMIA , HORSE , OIE VALIDATION , SYNTHETIC PEPTIDES
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 15.46Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/203439
URL: https://onlinelibrary.wiley.com/doi/10.1111/evj.13555
DOI: http://dx.doi.org/10.1111/evj.13555
Colecciones
Articulos(IMBECU)
Articulos de INST. DE MEDICINA Y BIO. EXP. DE CUYO
Citación
Russi, Romina Cecilia; García, Lucila; Cámara, María Silvia; Soutullo, Adriana Rosa; Validation of an indirect in-house ELISA using synthetic peptides to detect antibodies anti-gp90 and gp45 of the equine infectious anaemia virus; Equine Veterinary Journal Ltd; Equine Veterinary Journal; 55; 1; 1-2022; 111-121
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES