Mostrar el registro sencillo del ítem

dc.contributor.author
Perrotta, Patricio Rene  
dc.contributor.author
Arevalo, Fernando Javier  
dc.contributor.author
Vettorazzi, Nelio Roberto  
dc.contributor.author
Zon, María Alicia  
dc.contributor.author
Fernández, Héctor  
dc.date.available
2023-05-19T14:31:39Z  
dc.date.issued
2012-02  
dc.identifier.citation
Perrotta, Patricio Rene; Arevalo, Fernando Javier; Vettorazzi, Nelio Roberto; Zon, María Alicia; Fernández, Héctor; Development of a very sensitive electrochemical magneto immunosensor for the direct determination of ochratoxin A in red wine; Elsevier Science SA; Sensors and Actuators B: Chemical; 162; 1; 2-2012; 327-333  
dc.identifier.issn
0925-4005  
dc.identifier.uri
http://hdl.handle.net/11336/198109  
dc.description.abstract
An electrochemical immunosensor (EI) for the determination of ochratoxin A (OTA) in red wine samples was developed. This immunosensor was based on Protein G functionalized magnetic beads (MBs) as solid phase for affinity reaction between OTA and OTA monoclonal antibody (mAbOTA). A carbon screen printed-electrodes (CSPE) system was used as electrochemical transduction element. This immunosensor was based on a direct competitive assay between OTA in wine samples and OTA labeled with horseradish peroxidase (HRP) (OTA-HRP). The HRP, in the presence of hydrogen peroxide catalyzes the oxidation of pyrocatechol to benzoquinone, whose back electrochemical reduction was detected on a CSPE by square wave voltammetry (SWV). The experimental variables involved in the immunosensor response to OTA were evaluated. The performance obtained for the EI was an analytical range of 0.01-20 ppb, limit of detection (LOD) of 0.008 ppb, and IC 50 = 0.272 ± 0.081 ppb. In addition, an acceptable accuracy with a relative standard deviation (RSD) of 5.56% and very good recoveries (92-110%) were found. This work shows the potential of our EI for the direct measurement of OTA in red wine samples combining SWV as electroanalytical technique with the MBs and CSPE. This EI has great advantages as direct measurement of red wine samples without a prior pretreatment, the small volume of sample, the short time consuming of experiences and LOD well below those established by the Regulatory Commission of the European Community (2 μg kg -1).  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science SA  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
IMMUNOSENSOR  
dc.subject
MAGNETIC BEADS  
dc.subject
OCHRATOXIN A  
dc.subject
SCREEN PRINTED-ELECTRODE  
dc.subject
SQUARE WAVE VOLTAMMETRY  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Development of a very sensitive electrochemical magneto immunosensor for the direct determination of ochratoxin A in red wine  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2023-05-18T14:40:50Z  
dc.journal.volume
162  
dc.journal.number
1  
dc.journal.pagination
327-333  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Perrotta, Patricio Rene. Universidad Nacional de Río Cuarto. Facultad de Ciencias Exactas Fisicoquímicas y Naturales. Departamento de Química. Área Electroquímica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Arevalo, Fernando Javier. Universidad Nacional de Río Cuarto. Instituto para el Desarrollo Agroindustrial y de la Salud. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto para el Desarrollo Agroindustrial y de la Salud; Argentina  
dc.description.fil
Fil: Vettorazzi, Nelio Roberto. Universidad Nacional de Río Cuarto; Argentina  
dc.description.fil
Fil: Zon, María Alicia. Universidad Nacional de Río Cuarto. Instituto para el Desarrollo Agroindustrial y de la Salud. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto para el Desarrollo Agroindustrial y de la Salud; Argentina  
dc.description.fil
Fil: Fernández, Héctor. Universidad Nacional de Río Cuarto; Argentina. Universidad Nacional de Río Cuarto. Facultad de Ciencias Exactas Fisicoquímicas y Naturales. Departamento de Química; Argentina  
dc.journal.title
Sensors and Actuators B: Chemical  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.snb.2011.12.089  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0925400511011798