Mostrar el registro sencillo del ítem

dc.contributor.author
Locatelli, Paola  
dc.contributor.author
Olea, Fernanda Daniela  
dc.contributor.author
De Lorenzi, Andrea  
dc.contributor.author
Salmo, Fabián  
dc.contributor.author
Vera Janavel, Gustavo  
dc.contributor.author
Hnatiuk, Anna  
dc.contributor.author
Guevara, Eduardo  
dc.contributor.author
Crottogini, Alberto Jose  
dc.date.available
2023-04-17T13:35:32Z  
dc.date.issued
2011-11  
dc.identifier.citation
Locatelli, Paola; Olea, Fernanda Daniela; De Lorenzi, Andrea; Salmo, Fabián; Vera Janavel, Gustavo; et al.; Reference values for echocardiographic parameters and indexes of left ventricular function in healthy, young adult sheep used in translational research: comparison with standardized values in humans; e-Century Publishing Corporation; International Journal of Clinical and Experimental Medicine; 4; 4; 11-2011; 258-264  
dc.identifier.issn
1940-5901  
dc.identifier.uri
http://hdl.handle.net/11336/194126  
dc.description.abstract
Ovine models of ischemic heart disease and cardiac failure are increasingly used in translational research. However, reliable extrapolation of the results to the clinical setting requires knowing if ovine normal left ventricular (LV) function is comparable to that of humans. We thus assessed for echocardiographic LV dimensions and indexes in a large normal adult sheep population and compared them with standardized values in normal human adults. Bidimensional and tissue Doppler echocardiograms were performed in 69 young adult Corriedale sheep under light sedation. LV dimensions and indexes of systolic and diastolic function were measured. Absolute and body surface areanormalized values were compared to those for normal adult humans and their statistical distribution was assessed. Normalized dimensions (except for end diastolic diameter) as well as ejection fraction and fractional shortening fell within the ranges established by the American Society of Echocardiography and European Association of Echocardiography for normal adult humans. Normalized end diastolic diameter exceeded the upper normal limit but got close to it when correcting for the higher heart mass/body surface area ratio of sheep with respect to humans. Diastolic parameters also fell within normal human ranges except for a slightly lower mitral deceleration time. All values exhibited a Gaussian distribution. We conclude that echocardiographic parameters of systolic and diastolic LV performance in young adult sheep can be reliably extrapolated to the adult human, thus supporting the use of ovine models of human heart disease in translational research.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
e-Century Publishing Corporation  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
ECHOCARDIOGRAPHY  
dc.subject
SHEEP  
dc.subject
LEFT VENTRICULAR FUNCTION  
dc.subject
OVINE MODELS  
dc.subject.classification
Otras Medicina Básica  
dc.subject.classification
Medicina Básica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Reference values for echocardiographic parameters and indexes of left ventricular function in healthy, young adult sheep used in translational research: comparison with standardized values in humans  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2023-04-14T15:49:44Z  
dc.identifier.eissn
1940-5901  
dc.journal.volume
4  
dc.journal.number
4  
dc.journal.pagination
258-264  
dc.journal.pais
Estados Unidos  
dc.journal.ciudad
Madison  
dc.description.fil
Fil: Locatelli, Paola. Universidad Favaloro. Instituto de Invest.en Cs.basicas. Departamento D/cs.fisiológicas,farmacológicas y Bioquímicas. Cátedra de Fisiología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Olea, Fernanda Daniela. Universidad Favaloro. Instituto de Invest.en Cs.basicas. Departamento D/cs.fisiológicas,farmacológicas y Bioquímicas. Cátedra de Fisiología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: De Lorenzi, Andrea. Fundación Favaloro; Argentina  
dc.description.fil
Fil: Salmo, Fabián. Fundación Favaloro; Argentina  
dc.description.fil
Fil: Vera Janavel, Gustavo. Universidad Favaloro. Instituto de Invest.en Cs.basicas. Departamento D/cs.fisiológicas,farmacológicas y Bioquímicas. Cátedra de Fisiología; Argentina  
dc.description.fil
Fil: Hnatiuk, Anna. Universidad Favaloro. Instituto de Invest.en Cs.basicas. Departamento D/cs.fisiológicas,farmacológicas y Bioquímicas. Cátedra de Fisiología; Argentina  
dc.description.fil
Fil: Guevara, Eduardo. Fundación Favaloro; Argentina  
dc.description.fil
Fil: Crottogini, Alberto Jose. Universidad Favaloro. Instituto de Invest.en Cs.basicas. Departamento D/cs.fisiológicas,farmacológicas y Bioquímicas. Cátedra de Fisiología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.journal.title
International Journal of Clinical and Experimental Medicine  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://e-century.us/web/journal_toc.php?journal=ijcem&volume=4&number=4