dc.description.abstract
Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to baremetal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Baishideng Publishing Group
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc/2.5/ar/
dc.subject
POLYMERS
dc.subject
DRUG ELUTING STENTS
dc.subject
BIODEGRADABLE POLYMERS ;
dc.subject
STENTS
dc.subject
THROMBOSIS
dc.subject
RESTENOSIS
dc.subject.classification
Sistemas Cardíaco y Cardiovascular
dc.subject.classification
Medicina Clínica
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
Advantages and disadvantages of biodegradable platforms in drug eluting stents
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2023-03-28T14:21:53Z
dc.identifier.eissn
1949-8462
dc.journal.volume
3
dc.journal.number
3
dc.journal.pagination
84-92
dc.journal.pais
Estados Unidos
dc.journal.ciudad
California
dc.description.fil
Fil: Rodriguez Granillo, Gaston Alfredo. Rutgers University; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Cardiológicas. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Investigaciones Cardiológicas; Argentina
dc.description.fil
Fil: Rubilar, Bibiana. Sanatorio "Otamendi y Miroli S.A.". Servicio de Diagnóstico por Imágenes. Departamento de Imágenes en Cardiología. Centro de Investigaciones Cardiovasculares; Argentina
dc.description.fil
Fil: Rodriguez Granillo, Gaston Alfredo. Sanatorio "Otamendi y Miroli S.A.". Servicio de Diagnóstico por Imágenes. Departamento de Imágenes en Cardiología. Centro de Investigaciones Cardiovasculares; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Cardiológicas. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Investigaciones Cardiológicas; Argentina
dc.description.fil
Fil: Rodriguez, Alfredo E.. Sanatorio "Otamendi y Miroli S.A.". Servicio de Diagnóstico por Imágenes. Departamento de Imágenes en Cardiología. Centro de Investigaciones Cardiovasculares; Argentina
dc.journal.title
World Journal of Cardiology
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.wjgnet.com/1949-8462/full/v3/i3/84.htm
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.4330/wjc.v3.i3.84
Archivos asociados