Raviolo, Mónica Ana; Esteve Romero, Josep; Briñon, Margarita Cristina; Stability-indicating micellar liquid chromatography method for three novel derivatives of zidovudine in aqueous and simulated gastric and intestinal fluids matrices; Elsevier Science; Journal of Chromatography - A; 1218; 18; 5-2011; 2540-2545  
dc.identifier.issn
0021-9673  
dc.identifier.uri
http://hdl.handle.net/11336/190223  
dc.description.abstract
This work studies the stability of three new anti-HIV agents which were obtained by the association of zidovudine (AZT) with different amino acids, such as leucine (AZT-Leu) and valine (AZT-Val), and one with an acid group (AZT-Ac). Before commercialisation, their stability in different matrices - simulated gastric fluid (SGF, pH 1.2) and simulated intestinal fluid (SIF, pH 6.8), both as the USP 32 Guideline indicates, and buffers (pH 1.2 and 6.8) - must be studied. To this end, a new stability-indicating micellar liquid chromatography (MLC) method has been optimised and validated. Measurements were based on the disappearance of reagents and the appearance of the only degradation product (AZT). This optimised and validated method used a C18 column and a mobile phase containing 0.05M sodium dodecyl sulphate-1% (v/v)1-butanol-0.01M NaH2PO4 (pH 3.0) at 30°C, and a flow rate of 1mLmin-1. Under these conditions, retention times were 1.4, 3.6, 6.3 and 9.5min for AZT-Ac, AZT, AZT-Val and AZT-Leu, respectively. Calibrations better than 0.9995, intra- and inter-day precisions below 1.08% and good recoveries (94.47-116.52%) and robustness (RSD less that 1.08%) were obtained and were adequate to analyse the four compounds. Finally, this MLC method was applied to achieve stability studies which resulted in the evidence that all the compounds followed a pseudo-first-order kinetics, and in the determination of their kinetic constants and half-life time. A reference method, applied in the same studies, validated the MLC method reported herein.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
GASTRIC AND INTESTINAL MATRICES  
dc.subject
MICELLAR LIQUID CHROMATOGRAPHY  
dc.subject
STABILITY-INDICATING HPLC METHODS  
dc.subject
ZIDOVUDINE DERIVATIVES  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Stability-indicating micellar liquid chromatography method for three novel derivatives of zidovudine in aqueous and simulated gastric and intestinal fluids matrices  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2023-03-10T14:28:52Z  
dc.journal.volume
1218  
dc.journal.number
18  
dc.journal.pagination
2540-2545  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Raviolo, Mónica Ana. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Departamento de Farmacia; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina  
dc.description.fil
Fil: Esteve Romero, Josep. Universitat Jaume I; España  
dc.description.fil
Fil: Briñon, Margarita Cristina. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Departamento de Farmacia; Argentina  
dc.journal.title
Journal of Chromatography - A  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0021967311002135  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.chroma.2011.02.018