Artículo
On the use of time windows for the determination of sound strength parameter G from uncalibrated room impulse responses measurements
Fecha de publicación:
03/2021
Editorial:
Elsevier
Revista:
Applied Acoustics
ISSN:
0003-682X
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
The sound strength parameter G is one of the most important objective parameters related to the acoustical quality of concert halls, opera houses, and chamber music halls. G at mid frequencies is highly correlated with the acoustic quality reported by music conductors and subjects with musical training. Measuring this parameter requires a calibrated sound source or the direct sound isolated using a suitable time window as in [B. Katz, In situ calibration of the sound strength parameter G, JASA 138 (2) (2015) EL167–EL173]. In this article, the performance of several window functions and lengths used to isolate the direct sound is investigated. Although the errors obtained for low frequencies are large, an error in the order of a just-noticeable-difference at mid frequencies is obtained for a 30 ms Flat-Top window centered around arrival time of direct sound.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(INAUT)
Articulos de INSTITUTO DE AUTOMATICA
Articulos de INSTITUTO DE AUTOMATICA
Citación
Accolti Mostazo, Ernesto Enrique; di Sciscio, Fernando; On the use of time windows for the determination of sound strength parameter G from uncalibrated room impulse responses measurements; Elsevier; Applied Acoustics; 178; 1080; 3-2021; 1-12
Compartir