Mostrar el registro sencillo del ítem
dc.contributor.author
Pinto, Licarion
dc.contributor.author
Díaz Nieto, César Horacio
dc.contributor.author
Zon, María Alicia
dc.contributor.author
Fernandez, Hector
dc.contributor.author
de Araujo, Mario Cesar Ugulino
dc.date.available
2022-11-30T16:06:15Z
dc.date.issued
2016-01
dc.identifier.citation
Pinto, Licarion; Díaz Nieto, César Horacio; Zon, María Alicia; Fernandez, Hector; de Araujo, Mario Cesar Ugulino; Handling time misalignment and rank deficiency in liquid chromatography by multivariate curve resolution: Quantitation of five biogenic amines in fish; Elsevier Science; Analytica Chimica Acta; 902; 1-2016; 59-69
dc.identifier.issn
0003-2670
dc.identifier.uri
http://hdl.handle.net/11336/179571
dc.description.abstract
Biogenic amines (BAs) are used for identifying spoilage in food. The most common are tryptamine (TRY), 2-phenylethylamine (PHE), putrescine (PUT), cadaverine (CAD) and histamine (HIS). Due to lack of chromophores, chemical derivatization with dansyl was employed to analyze these BAs using high performance liquid chromatography with a diode array detector (HPLC-DAD). However, the derivatization reaction occurs with any primary or secondary amine, leading to co-elution of analytes and interferents with identical spectral profiles, and thus causing rank deficiency. When the spectral profile is the same and peak misalignment is present on the chromatographic runs, it is not possible to handle the data only with Multivariate Curve Resolution and Alternative Least Square (MCR-ALS), by augmenting the time, or the spectral mode. A way to circumvent this drawback is to receive information from another detector that leads to a selective profile for the analyte. To overcome both problems, (tri-linearity break in time, and spectral mode), this paper proposes a new analytical methodology for fast quantitation of these BAs in fish with HPLC-DAD by using the icoshift algorithm for temporal misalignment correction before MCR-ALS spectral mode augmented treatment. Limits of detection, relative errors of prediction (REP) and average recoveries, ranging from 0.14 to 0.50 μg mL-1, 3.5-8.8% and 88.08%-99.68%, respectively. These are outstanding results obtained, reaching quantification limits for the five BAs much lower than those established by the Food and Agriculture Organization of the United Nations and World Health Organization (FAO/WHO), and the European Food Safety Authority (EFSA), all without any pre-concentration steps. The concentrations of BAs in fish samples ranged from 7.82 to 29.41 μg g-1, 8.68-25.95 μg g-1, 4.76-28.54 μg g-1, 5.18-39.95 μg g-1 and 1.45-52.62 μg g-1 for TRY, PHE, PUT, CAD, and HIS, respectively. In addition, the proposed method spends less than 4 min in an isocratic run, consuming less solvent in accordance with the principles of green analytical chemistry.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
BIOGENIC AMINES
dc.subject
DANSYL DERIVATIZATION
dc.subject
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
dc.subject
ICOSHIFT
dc.subject
MULTIVARIATE CURVE RESOLUTION
dc.subject
RANK DEFICIENCY
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Handling time misalignment and rank deficiency in liquid chromatography by multivariate curve resolution: Quantitation of five biogenic amines in fish
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2022-11-30T12:07:37Z
dc.journal.volume
902
dc.journal.pagination
59-69
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Pinto, Licarion. Universidade Estadual da Paraiba; Brasil
dc.description.fil
Fil: Díaz Nieto, César Horacio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Nacional de Río Cuarto. Facultad de Ciencias Exactas Fisicoquímicas y Naturales. Departamento de Química; Argentina
dc.description.fil
Fil: Zon, María Alicia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Nacional de Río Cuarto. Facultad de Ciencias Exactas Fisicoquímicas y Naturales. Departamento de Química; Argentina
dc.description.fil
Fil: Fernandez, Hector. Universidad Nacional de Río Cuarto. Facultad de Ciencias Exactas Fisicoquímicas y Naturales. Departamento de Química; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina
dc.description.fil
Fil: de Araujo, Mario Cesar Ugulino. Universidade Estadual da Paraiba; Brasil
dc.journal.title
Analytica Chimica Acta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0003267015013227?via%3Dihub
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.aca.2015.10.043
Archivos asociados