Utilidad del score HEART con troponina T de alta sensibilidad para la evaluación de pacientes con dolor torácico

Título: Usefulness of the HEART Score with High-Sensitivity Troponin T for the Evaluation of Patients with Chest Pain
Cortes, Marcia M.; Lambardi, Florencia; Ariz Navarreta, Paula; Resi, Silvana; Arbucci, Rosina; Maite Borda; Trivi, Marcelo Ricardo; Alves de Lima, Alberto EnriqueIcon ; Costabel, Juan Pablo
Fecha de publicación: 07/2018
Editorial: Sociedad Argentina de Cardiología
Revista: Revista Argentina de Cardiología
ISSN: 1850-3748
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Sistemas Cardíaco y Cardiovascular

Resumen

 
Introducción: El score HEART consiste en una prueba sencilla que fue diseñada para estratificar a los pacientes que consultan al servicio de emergencias por dolor torácico, según su riesgo de presentar un síndrome coronario agudo a corto plazo. Fue creado inicialmente con troponina de cuarta generación, pero el advenimiento de la troponina de alta sensibilidad impuso su incorporación al score y la reevaluación de su comportamiento. Objetivo: Nos propusimos evaluar el comportamiento del score HEART con troponina de alta sensibilidad. Material y métodos: Se realizó un estudio prospectivo que incluyó 1464 pacientes (p) que consultaron al servicio de emergencia por dolor torácico y que tenían electrocardiograma sin elevación del segmento ST. Se evaluó la incidencia de MACE (combinado de infarto agudo de miocardio, muerte y revascularización) a 30 días. Resultados: El índice clasificó 739 pacientes (50,5 %) como de bajo riesgo, 515 pacientes (35,2%) de riesgo intermedio y 210 pacientes (14,3%) de alto riesgo. La incidencia de la combinación de infarto agudo de miocardio, muerte y revascularización fue del 1,35% en el primer grupo; del 20%, en el segundo; y del 71%, en el tercero (long rank test p < 0,001). El área bajo la curva global para la combinación de infarto agudo de miocardio, muerte y revascularización fue de 0,91 (0,89-0,93). Conclusiones: El score HEART que utiliza troponina de alta sensibilidad tiene una gran capacidad para clasificar pacientes con dolor torácico de acuerdo con su riesgo de presentar eventos cardiovasculares en el corto plazo.
 
Background: The HEART score consists of a simple test designed to stratify patients who consult the emergency department for chest pain, according to their risk of presenting an acute coronary syndrome in the short term. It was initially created with a fourth-generation troponin, but the advent of high-sensitivity cardiac troponin T required its incorporation into the score and the re-evaluation of its behavior. Objectives: The aim of this study was to evaluate the behavior of the HEART score with high sensitivity cardiac troponin T. Methods: A prospective study was conducted including 1,464 patients who consulted at the emergency department due chest pain, with a non-ST-segment elevation electrocardiogram. The incidence of MACE (composite of acute myocardial infarction, death and revascularization) at 30 days was evaluated. Results: The index classified 739 patients (50.5%) as low risk, 515 (35.2%) as intermediate risk and 210 (14.3%) as high risk patients. The composite of acute myocardial infarction, death and revascularization incidence was 1.35% in the first group, 20%, in the second group and 71%, in the third group (log-rank test p<0.001). The area under the global curve for the composite of acute myocardial infarction, death and revascularization was 0.91 (0.89-0.93). Conclusions: The HEART score using high-sensitivity cardiac troponin T has a great capacity to classify patients with chest pain according to their risk of presenting cardiovascular events in the short term.
 
Palabras clave: Dolor de pecho , Sindrome coronario agudo , Troponina T , Medición de riesgo
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 282.1Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial 2.5 Unported (CC BY-NC 2.5)
Identificadores
URI: http://hdl.handle.net/11336/177282
URL: http://www.scielo.org.ar/scielo.php?script=sci_arttext&pid=S1850-374820180005000
Colecciones
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Citación
Cortes, Marcia M.; Lambardi, Florencia; Ariz Navarreta, Paula; Resi, Silvana; Arbucci, Rosina; et al.; Utilidad del score HEART con troponina T de alta sensibilidad para la evaluación de pacientes con dolor torácico; Sociedad Argentina de Cardiología; Revista Argentina de Cardiología; 86; 7-2018; 333-337
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES