dc.description.abstract
Quinolone is a family of widely prescript antibiotics in veterinary medicine. Their excessive use can be causative of quinolone residues in foodstuffs of animal origin. Therefore, a magneto immunofluorescence assay in microwell plate has been developed and validated to screen quinolone in bovine milk. The assay is based on an indirect competitive method where the quinolone in the milk sample competed with the quinolone immobilized on magnetic beads for the anti-quinolone antibody. Then, an anti-IgG antibody–labeled peroxidase and their respective substrates were added and the fluorescent signal was indirectly related with the quinolone concentration. Recoveries of quinolones from 82 to 102% were obtained in skimmed, whole, and raw milk samples in concordance with the results obtained by a reference method. Seven quinolones were evaluated quantitatively by the method, obtaining limits of detection of 10 μg L−1 for ciprofloxacin and marbofloxacin, 13 μg L−1 for enrofloxacin and danofloxacin, 22 μg L−1 for norfloxacin, 29 μg L−1 for sarafloxacin, and 30 μg L−1 for ofloxacin. For the screening detection of quinolones, ciprofloxacin was used as model with decision limit (CCα) and detection capability (CCβ) of 103 and 106 μg L−1, respectively. High cross-reactivity (> 100%) was obtained to all assayed quinolones while negligible cross-reactivity (< 0.1%) to other antibiotics (β-lactams, aminoglycosides, macrolides, tetracyclines, and sulfamides) was observed. The validation provided evidence that the method is suitable to be applied in routine analysis for the detection of quinolones in bovine milk.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Springer  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
BOVINE MILK  
dc.subject
IMMUNOFLUORESCENCE ASSAY  
dc.subject
MAGNETIC BEAD  
dc.subject
QUINOLONE  
dc.subject
SCREENING METHOD  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Magneto immunofluorescence assay for quinolone detection in bovine milk  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2022-09-22T15:20:51Z  
dc.journal.volume
13  
dc.journal.number
8  
dc.journal.pagination
1539-1547  
dc.journal.pais
Alemania  
dc.journal.ciudad
Berlín  
dc.description.fil
Fil: Kergaravat, Silvina Vanesa. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina  
dc.description.fil
Fil: Nagel, Orlando Guillermo. Universidad Nacional del Litoral. Facultad de Ciencias Veterinarias. Departamento de Ciencias Básicas; Argentina  
dc.description.fil
Fil: Althaus, Rafael Lisandro. Universidad Nacional del Litoral. Facultad de Ciencias Veterinarias. Departamento de Ciencias Básicas; Argentina  
dc.description.fil
Fil: Hernández, Silvia Raquel. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina  
dc.journal.title
Food Analytical Methods  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://link.springer.com/10.1007/s12161-020-01749-9  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s12161-020-01749-9