Mostrar el registro sencillo del ítem
dc.contributor.author
Gholivand, Mohammad Bagher
dc.contributor.author
Jalalvand, Ali R.
dc.contributor.author
Goicoechea, Hector Casimiro
dc.contributor.author
Gargallo, Raimundo
dc.contributor.author
Skov, Thomas
dc.contributor.author
Paimard, Giti
dc.date.available
2017-06-01T19:45:40Z
dc.date.issued
2015-01
dc.identifier.citation
Gholivand, Mohammad Bagher; Jalalvand, Ali R.; Goicoechea, Hector Casimiro; Gargallo, Raimundo; Skov, Thomas; et al.; Combination of electrochemistry with chemometrics to introduce an efficient analytical method for simultaneous quantification of five opium alkaloids in complex matrices; Elsevier; Talanta; 131; 1-2015; 26-37
dc.identifier.issn
0039-9140
dc.identifier.uri
http://hdl.handle.net/11336/17303
dc.description.abstract
For the first time, an analytical methodology based on differential pulse voltammetry (DPV) at a glassy carbon electrode (GCE) and integration of three efficient strategies including variable selection based on ant colony optimization (ACO), mathematical pre-processing selection by genetic algorithm (GA), and sample selection (SS) through a distance-based procedure to improve partial least squares-1 (PLS-1, ACO-GA-SS-PLS-1) multivariate calibration (MVC) for the simultaneous determination of five opium alkaloids including morphine (MOP), noscapine (NOP), thebaine (TEB), codeine (COD), and papaverine (PAP) was used and validated. The baselines of the DPV signals were modeled as a smooth curve, using P-splines, a combination of B-splines and a discrete roughness penalty. After subtraction of the baseline we got a signal with a two-component probability density. One component was for the peaks and it was approximated by a uniform distribution on the potential axis. The other component was for the observed noise around the baseline. Some sources of bi-linearity deviation for electrochemical data were discussed and analyzed. The lack of bi-linearity was tackled by potential shift correction using correlation optimized warping (COW) algorithm. The MVC model was developed as a quinternary calibration model in a blank human serum sample (drug-free) provided by a healthy volunteer to regard the presence of a strong matrix effect which may be caused by the possible interferents present in the serum, and it was validated and tested with two independent sets of analytes mixtures in the blank and actual human serum samples, respectively. Fortunately, the proposed methodology was successful in simultaneous determination of MOP, NOP, TEB, COD, and PAP in both blank and actual human serum samples and its results were satisfactory comparable to those obtained by applying the reference method based on high performance liquid chromatography-ultraviolet detection (HPLC-UV)
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.subject
Ant Colony Optimization
dc.subject
Sample Selection
dc.subject
Genetic Algorithm
dc.subject
Multivariate Calibration
dc.subject
Opium Alkaloids
dc.subject
Simultaneous Determination
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Combination of electrochemistry with chemometrics to introduce an efficient analytical method for simultaneous quantification of five opium alkaloids in complex matrices
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2017-05-04T18:43:37Z
dc.journal.volume
131
dc.journal.pagination
26-37
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Gholivand, Mohammad Bagher. Razi University. Faculty of Chemistry; Irán
dc.description.fil
Fil: Jalalvand, Ali R.. Razi University. Faculty of Chemistry; Irán. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Laboratorio de Química Analitica; Argentina
dc.description.fil
Fil: Goicoechea, Hector Casimiro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Laboratorio de Química Analitica; Argentina
dc.description.fil
Fil: Gargallo, Raimundo. Universidad de Barcelona; España
dc.description.fil
Fil: Skov, Thomas. Universidad de Copenhagen; Dinamarca
dc.description.fil
Fil: Paimard, Giti. Razi University. Faculty of Chemistry; Irán
dc.journal.title
Talanta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2014.07.053
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0039914014006213
Archivos asociados