dc.identifier.citation
Gholivand, Mohammad Bagher; Jalalvand, Ali R.; Goicoechea, Hector Casimiro; Gargallo, Raimundo; Skov, Thomas; et al.; Combination of electrochemistry with chemometrics to introduce an efficient analytical method for simultaneous quantification of five opium alkaloids in complex matrices; Elsevier; Talanta; 131; 1-2015; 26-37  
dc.identifier.issn
0039-9140  
dc.identifier.uri
http://hdl.handle.net/11336/17303  
dc.description.abstract
For the first time, an analytical methodology based on differential pulse voltammetry (DPV) at a glassy carbon electrode (GCE) and integration of three efficient strategies including variable selection based on ant colony optimization (ACO), mathematical pre-processing selection by genetic algorithm (GA), and sample selection (SS) through a distance-based procedure to improve partial least squares-1 (PLS-1, ACO-GA-SS-PLS-1) multivariate calibration (MVC) for the simultaneous determination of five opium alkaloids including morphine (MOP), noscapine (NOP), thebaine (TEB), codeine (COD), and papaverine (PAP) was used and validated. The baselines of the DPV signals were modeled as a smooth curve, using P-splines, a combination of B-splines and a discrete roughness penalty. After subtraction of the baseline we got a signal with a two-component probability density. One component was for the peaks and it was approximated by a uniform distribution on the potential axis. The other component was for the observed noise around the baseline. Some sources of bi-linearity deviation for electrochemical data were discussed and analyzed. The lack of bi-linearity was tackled by potential shift correction using correlation optimized warping (COW) algorithm. The MVC model was developed as a quinternary calibration model in a blank human serum sample (drug-free) provided by a healthy volunteer to regard the presence of a strong matrix effect which may be caused by the possible interferents present in the serum, and it was validated and tested with two independent sets of analytes mixtures in the blank and actual human serum samples, respectively. Fortunately, the proposed methodology was successful in simultaneous determination of MOP, NOP, TEB, COD, and PAP in both blank and actual human serum samples and its results were satisfactory comparable to those obtained by applying the reference method based on high performance liquid chromatography-ultraviolet detection (HPLC-UV)  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Ant Colony Optimization  
dc.subject
Sample Selection  
dc.subject
Genetic Algorithm  
dc.subject
Multivariate Calibration  
dc.subject
Opium Alkaloids  
dc.subject
Simultaneous Determination  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Combination of electrochemistry with chemometrics to introduce an efficient analytical method for simultaneous quantification of five opium alkaloids in complex matrices  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2017-05-04T18:43:37Z  
dc.journal.volume
131  
dc.journal.pagination
26-37  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Gholivand, Mohammad Bagher. Razi University. Faculty of Chemistry; Irán  
dc.description.fil
Fil: Jalalvand, Ali R.. Razi University. Faculty of Chemistry; Irán. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Laboratorio de Química Analitica; Argentina  
dc.description.fil
Fil: Goicoechea, Hector Casimiro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Laboratorio de Química Analitica; Argentina  
dc.description.fil
Fil: Gargallo, Raimundo. Universidad de Barcelona; España  
dc.description.fil
Fil: Skov, Thomas. Universidad de Copenhagen; Dinamarca  
dc.description.fil
Fil: Paimard, Giti. Razi University. Faculty of Chemistry; Irán  
dc.journal.title
Talanta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2014.07.053  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0039914014006213