Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Desarrollo de un método de detección y cuantificación de residuos de tetraciclina en quesos por cromatografía liquida de alta eficiencia (HPLC)

Merchán Castellanos, Nuri Andrea; Aguilera Becerra, Astrid Maribel; Espinosa Manrique, Wilfred EdilbertoIcon
Fecha de publicación: 05/2021
Editorial: Universidad de Zulia
Revista: Revista Científica
ISSN: 0798-2259
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Química Analítica

Resumen

 
El objetivo del estudio fue desarrollar una metodología de alta precisión que permitiera detectar y cuantificar residuos de tetraciclina en quesos aplicando la técnica analítica de cromatografía liquida de alta eficiencia (HPLC). Como resultado se generó un método mediante el cual se detectaron residuos de tetraciclina en matrices biológicas complejas como el queso. Se establecieron condiciones de temperatura (30 °C), longitud de onda (265 nanómetros (nm)), volumen (20 microlitros (μL)) y flujo de inyección (1 mililitro (mL)/minutos(min)), así como la fase móvil utilizada con metanol: acetonitrilo: ácido oxálico (74:13:13% volumen/volumen (v/v)) para la corrida en el equipo HPLC. Se obtuvieron curvas de calibración con coeficiente de determinación (R2) próximos a 1, con concentraciones de soluciones estándar de 2,0 partes por millón (ppm), 1,5 ppm, 1,0 ppm, 0,8 ppm, 0,6 ppm, 05 ppm, para tetraciclina. El método presentó límites de cuantificación para tetraciclina de 0,1 miligramos/Litro (mg/L) y límite de detección de 0,2 mg/L, valores que se encuentran por debajo de los límites máximos permisibles por la norma colombiana para leches. Por otra parte, se establecieron condiciones para realizar el proceso de extracción de los residuos de antibióticos en matrices biológicas complejas, como buffer, tiempo y temperatura de centrifugación, tipo de cartucho para purificación y reactivo de recuperación entre otras. Se concluye que el porcentaje de recuperación fue adecuado y se evidencia que el método permite la detección de los residuos de antibióticos a partir de muestras biológicas.
 
The aim of this study was to develop a high-precision methodology that would allow the detection and quantification of tetracycline residues in cheeses using the Liquid Chromatography High Efficiency (HPLC) analytical technique. As a result, a method was generated in which tetracycline residues were detected in complex biological matrices such as cheese. Conditions of temperature (30 ° C), wave length (265 nanometres (nm)), volume (20 microlitres (µL) and injection flow (1 millilitres mL / minutes (min)) were established, as well as the mobile phase used with methanol: acetonitrile: oxalic acid (74 : 13: 13% volume/ volume (v/v)) for the assay on the HPLC machine. Calibration curves with coefficient of determination (R2) close to 1 were obtained, with concentrations of standard solutions of 2.0 parts per million (ppm), 1.5 ppm, 1.0 ppm, 0.8 ppm, 0.6 ppm, 0.5 ppm, for tetracycline. The method presented quantification limits for tetracycline of 0.1 milligrams/Litter (mg/L) and detection limit of 0.02 mg/L, values that are below the maximum limits allowed by the Colombian standard for milk. On the other hand, conditions were established to carry out the extraction process of the antibiotic residues in complex biological matrices, such as buffer, centrifugation time and temperature, type of cartridge for purification and recovery reagent, among others. It is concluded that the recovery percentage was adequate, and it is evident that the method allows the detection of antibiotic residues from biological samples.
 
Palabras clave: Cromatografía líquida de alta resolución (HPLC) , Queso , Antimicrobianos , Tetraciclinas
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 775.0Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/172428
URL: https://produccioncientificaluz.org/index.php/cientifica/article/view/35976
Colecciones
Articulos(INIFTA)
Articulos de INST.DE INV.FISICOQUIMICAS TEORICAS Y APLIC.
Citación
Merchán Castellanos, Nuri Andrea; Aguilera Becerra, Astrid Maribel; Espinosa Manrique, Wilfred Edilberto; Desarrollo de un método de detección y cuantificación de residuos de tetraciclina en quesos por cromatografía liquida de alta eficiencia (HPLC); Universidad de Zulia; Revista Científica; 30; 4; 5-2021; 180-185
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES