Ventilator output splitting interface ‘ACRA’: Description and evaluation in lung simulators and in an experimental ARDS animal model

Otero, Pablo Ezequiel; Tarragona, Lisa; Zaccagnini, Andrea Silvia; Verdier, Natali; Ceballos, Martin; Gogniat, Emiliano; Cabaleiro, Juan MartinIcon ; D'adamo, Juan Gastón LeonelIcon ; Duriez, Thomas Pierre CornilIcon ; Garcia Eijo, Pedro Manuel; Artana, Guillermo OsvaldoIcon
Fecha de publicación: 08/2021
Editorial: Public Library of Science
Revista: Plos One
ISSN: 1932-6203
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias Veterinarias

Resumen

The current COVID-19 pandemic has led the world to an unprecedented global shortage of ventilators, and its sharing has been proposed as an alternative to meet the surge. This study outlines the performance of a preformed novel interface called’ACRA’, designed to split ventilator outflow into two breathing systems. The’ACRA’ interface was built using medical use approved components. It consists of four unidirectional valves, two adjustable flow-restrictor valves placed on the inspiratory limbs of each unit, and one adjustable PEEP valve placed on the expiratory limb of the unit that would require a greater PEEP. The interface was interposed between a ventilator and two lung units (phase I), two breathing simulators (phase II) and two live pigs with heterogeneous lung conditions (phase III). The interface and ventilator adjustments tested the ability to regulate individual pressures and the resulting tidal volumes. Data were analyzed using Friedman and Wilcoxon tests test (p < 0.05). Ventilator outflow splitting, independent pressure adjustments and individual tidal volume monitoring were feasible in all phases. In all experimental measurements, dual ventilation allowed for individual and tight adjustments of the pressure, and thus volume delivered to each paired lung unit without affecting the other unit’s ventilation—all the modifications performed on the ventilator equally affected both paired lung units. Although only suggested during a dire crisis, this experiment supports dual ventilation as an alternative worth to be considered.
Palabras clave: COVID-19 , SHARED VENTILATION , EXHALATORY DYNAMICS
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.060Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution 2.5 Unported (CC BY 2.5)
Identificadores
URI: http://hdl.handle.net/11336/170015
URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0256469
DOI: http://dx.doi.org/10.1371/journal.pone.0256469
Colecciones
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Citación
Otero, Pablo Ezequiel; Tarragona, Lisa; Zaccagnini, Andrea Silvia; Verdier, Natali; Ceballos, Martin; et al.; Ventilator output splitting interface ‘ACRA’: Description and evaluation in lung simulators and in an experimental ARDS animal model; Public Library of Science; Plos One; 16; 8; 8-2021; 1-15
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES