dc.contributor.author
Narata, Ana Paula
dc.contributor.author
Obradó, Laura
dc.contributor.author
Moyano, Raquel Kalé
dc.contributor.author
Macho, Juan M.
dc.contributor.author
Blasco, Jordi
dc.contributor.author
Rueda, Antonio López
dc.contributor.author
Roman, Luis San
dc.contributor.author
Remollo, Sebastian
dc.contributor.author
Marinelli, Claudia Beatriz
dc.contributor.author
Cepeda, Rosana
dc.contributor.author
Fernández, Héctor
dc.contributor.author
Larrabide, Ignacio
dc.date.available
2022-08-08T13:51:45Z
dc.date.issued
2021-09
dc.identifier.citation
Narata, Ana Paula; Obradó, Laura; Moyano, Raquel Kalé; Macho, Juan M.; Blasco, Jordi; et al.; Cerebral aneurysm occlusion at 12-month follow-up after flow-diverter treatment: statistical modeling for V&V with real-world data; Frontiers Media; Frontiers in Medical Technology; 3; 9-2021; 1-11
dc.identifier.uri
http://hdl.handle.net/11336/164520
dc.description.abstract
Background: Flow-Diverter (FD) porosity has been pointed as a critical factor in theocclusion of cerebral aneurysms after treatment.Objective: Verification and Validation of computational models in terms of predictivecapacity, relating FD porosity and occlusion after cerebral aneurysms treatment.Methods: Sixty-four aneurysms, with pre-treatment and follow-up images, wereconsidered. Patient demographics and aneurysm morphological information werecollected. The computational simulation provided by ANKYRAS provided FD porosity,expansion, and mesh angle. FD occlusion was assessed and recorded from follow-upimages. Multiple regression Logit and analysis of covariance (ANCOVA) models wereused to model the data with both categorical and continuous models.Results: Occlusion of the aneurysm after 12 months was affected by aneurysmmorphology but not by FD mesh morphology. A Time-To-Occlusion (TTO) of 6.92 monthson average was observed with an SE of 0.24 months in the aneurysm populationsurveyed. TTO was estimated with statistical significance from the resulting model forthe data examined and was capable of explaining 92% of the data variation.Conclusions: Porosity was found to have the most correction power when assessingTTO, proving its importance in the process of aneurysm occlusion. Still, further Verificationand Validation (V&V) of treatment simulation in more extensive, multi-center, andrandomized databases is required.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Frontiers Media
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by/2.5/ar/
dc.subject
CEREBRAL ANEURYSMS
dc.subject
FLOW DIVERTER
dc.subject
DEVICE SIZING
dc.subject
DEVICE POROSITY
dc.subject
TIME-TO-OCCLUSION
dc.subject.classification
Ciencias de la Información y Bioinformática
dc.subject.classification
Ciencias de la Computación e Información
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Cerebral aneurysm occlusion at 12-month follow-up after flow-diverter treatment: statistical modeling for V&V with real-world data
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2022-08-04T15:08:28Z
dc.identifier.eissn
2673-3129
dc.journal.volume
3
dc.journal.pagination
1-11
dc.journal.pais
Suiza
dc.journal.ciudad
Lausana
dc.description.fil
Fil: Narata, Ana Paula. Hôpitaux de Tours; Francia
dc.description.fil
Fil: Obradó, Laura. Galgo Medical S. L.; España
dc.description.fil
Fil: Moyano, Raquel Kalé. Galgo Medical S. L.; España
dc.description.fil
Fil: Macho, Juan M.. Hospital Clinic of Barcelona; España
dc.description.fil
Fil: Blasco, Jordi. Hospital Clinic of Barcelona; España
dc.description.fil
Fil: Rueda, Antonio López. Hospital Clinic of Barcelona; España
dc.description.fil
Fil: Roman, Luis San. Hospital Clinic of Barcelona; España
dc.description.fil
Fil: Remollo, Sebastian. Hospital Universitari Germans Trias i Pujol; España
dc.description.fil
Fil: Marinelli, Claudia Beatriz. Universidad Nacional del Centro de la Provincia de Buenos Aires; Argentina
dc.description.fil
Fil: Cepeda, Rosana. Universidad Nacional del Centro de la Provincia de Buenos Aires; Argentina
dc.description.fil
Fil: Fernández, Héctor. Galgo Medical S. L.; España
dc.description.fil
Fil: Larrabide, Ignacio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Galgo Medical S. L.; España
dc.journal.title
Frontiers in Medical Technology
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.frontiersin.org/articles/10.3389/fmedt.2021.705003/full
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.3389/fmedt.2021.705003
Archivos asociados