Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Monitoreo de la evapotranspiración real horaria por medio del balance energético y un lisímetro de pesada

Título: Monitoring the hourly actual evapotranspiration through the energy balance and a weighing lysimeter
Faramiñán, Adán Matías GabrielIcon ; Carmona, FacundoIcon ; Rivas, Raúl Eduardo; Degano, María FlorenciaIcon ; Abadie, Paula AndreaIcon
Fecha de publicación: 01/2021
Editorial: Instituto Geológico y Minero de España
Revista: Boletín Geológico y Minero
ISSN: 0366-0176
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias de la Tierra y relacionadas con el Medio Ambiente

Resumen

 
Conociendo adecuadamente en espacio y tiempo la evapotranspiración es posible gestionar y planificar el manejo hídrico que se le da a una cuenca de llanura. Se estudia de forma indirecta a escala local por medio de estaciones agrometeorológicas, o a escala regional con el uso de datos de satélite. Para tener fiabilidad de los modelos utilizados, es de suma importancia validar la información generada con medidas directas. De acuerdo con esto, se presenta el estudio de medidas directas de evapotranspiración en suelos arcillosos cubiertos por gramíneas en condiciones de secano para la validación de un modelo simple de balance energético en la región Pampa húmeda del centro-oeste de la Argentina. Para ello, se utilizaron registros horarios de una estación de balance de energía y se relacionaron con medidas directas de un lisímetro de pesada durante los meses de febrero-marzo y septiembre de 2017. Con el método energético se obtuvieron valores aproximados de evapotranspiración real para registros máximos de humedad edáfica (0,01-0,15 mm hora-1), mostrando mayores diferencias (0,1-0,35 mm hora-1) cuando la humedad del suelo tiende a valores mínimos. En este trabajo se demostró que un modelo simplificado del balance de energía para determinar la evapotranspiración como flujo residual es aplicable para áreas con coberturas de referencia definidas (Allen et al., 1998), permitiendo simplificaciones en las medidas de resistencias aerodinámicas y del cultivo. Este aporte brinda información necesaria para la validación de modelos satelitales aplicados a zonas de llanura, en donde la evapotranspiración es un término de relevancia.
 
By having sufficient knowledge about evapotranspiration in space and time, it is possible to manage and plan the water management of a basin. Evapotranspiration can be obtained indirectly at a local scale through information recorded in agrometeorological stations, or regionally with the use of satellite data. In order to have reliable models, it is very important to validate the information generated with direct measures of evapotranspiration. Therefore, direct measurements of evapotranspiration in clay secano-soils covered by grasses and the use of the data generated for the validation of indirect measurements are presented in this study. To achieve this, hourly data from an energy balance station and direct measurements of a weighing lysimeter were used to study the water loss during two experimental campaigns carried out in Tandil (Argentina), in the months February-March and September 2017. The comparison of the methods was made for different moisture conditions of the soil. The energy balance model estimates approximate values of actual evapotranspiration for maximum values of soil moisture (0.01-0.15 mm hour-1), showing greater differences (0.1-0.35 mm hour-1) when the soil moisture tends to minimum values. However, it was demonstrated that a simple one-level model to determine the latter variable is applicable for areas with reference coverage, allowing simplifications in aerodynamic and crop resistance measurements (Allen et al. 1998). This contribution provides necessary information for the validation of satellite models applied to plains areas, where evapotranspiration is a term of great importance.
 
Palabras clave: BALANCE DE ENERGÍA , HUMEDAD DEL SUELO , LISÍMETRO , LLANURA
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 533.3Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/164282
URL: https://www.igme.es/boletin/2021/132_1-2.htm
DOI: https://www.igme.es/Boletin/2021/132_1-2/BGM_132-1-2_Art-5.pdf
DOI: http://dx.doi.org/10.21701/bolgeomin.132.1-2.005
Colecciones
Articulos(CCT - TANDIL)
Articulos de CTRO CIENTIFICO TECNOLOGICO CONICET - TANDIL
Citación
Faramiñán, Adán Matías Gabriel; Carmona, Facundo; Rivas, Raúl Eduardo; Degano, María Florencia; Abadie, Paula Andrea; Monitoreo de la evapotranspiración real horaria por medio del balance energético y un lisímetro de pesada; Instituto Geológico y Minero de España; Boletín Geológico y Minero; 132; 1-2; 1-2021; 47-56
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES