Mostrar el registro sencillo del ítem

dc.contributor.author
Gutiérrez, Alejandro Figar  
dc.contributor.author
Bonofiglio, Francisco  
dc.contributor.author
Karippacheril, John George  
dc.contributor.author
Redelico, Francisco Oscar  
dc.contributor.author
Iturralde, Maria de Los Angeles  
dc.date.available
2022-07-07T02:41:59Z  
dc.date.issued
2022-02  
dc.identifier.citation
Gutiérrez, Alejandro Figar; Bonofiglio, Francisco; Karippacheril, John George; Redelico, Francisco Oscar; Iturralde, Maria de Los Angeles; Heart rate variability follow-up during COVID-19: A case report; Korean Society of Anesthesiologists; Korean Journal of Anesthesiology; 75; 1; 2-2022; 86-96  
dc.identifier.issn
2005-6419  
dc.identifier.uri
http://hdl.handle.net/11336/161489  
dc.description.abstract
Background: To detect an early increase in the inflammatory response might prove to be vital for mitigating the deleterious effects of the disease over time. Case: A 52-year-old obese man with moderate asthma and hypertension, who developed COVID-19 and had moderate symptoms, used a wearable device to record heart rate variability (HRV) during his illness. He had low parasympathetic tone, which decreased daily until it reached almost 2 standard deviations (SD) below normal values at the end of the second week. His sympathetic tone increased from > 3 SD to > 5 SD. Conclusions: These findings suggest an altered modulation of the sympathetic and para-sympathetic nervous systems in COVID-19, such that the sympathetic tone is augmented and the parasympathetic tone is reduced. Population norms of COVID-19 infections should be further studied over the short-term and using 24 h HRV measurements.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Korean Society of Anesthesiologists  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
AMBULATORY MONITORING  
dc.subject
AUTONOMIC NERVOUS SYSTEM  
dc.subject
COMPUTER-ASSISTED SIGNAL PROCESSING  
dc.subject
COVID-19  
dc.subject
HEART RATE  
dc.subject
WEARABLE ELECTRONIC DEVICES  
dc.subject.classification
Otras Biotecnologías de la Salud  
dc.subject.classification
Biotecnología de la Salud  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Heart rate variability follow-up during COVID-19: A case report  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2022-07-04T19:40:32Z  
dc.identifier.eissn
2005-7563  
dc.journal.volume
75  
dc.journal.number
1  
dc.journal.pagination
86-96  
dc.journal.pais
Corea del Sur  
dc.description.fil
Fil: Gutiérrez, Alejandro Figar. Hospital Italiano. Departamento de Informática En Salud.; Argentina  
dc.description.fil
Fil: Bonofiglio, Francisco. Hospital Italiano. Departamento de Informática En Salud.; Argentina  
dc.description.fil
Fil: Karippacheril, John George. Cleveland Clinic Abu Dhabi; Emiratos Arabes Unidos  
dc.description.fil
Fil: Redelico, Francisco Oscar. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Oficina de Coordinacion Administrativa Houssay. Instituto de Medicina Traslacional E Ingenieria Biomedica. - Hospital Italiano. Instituto de Medicina Traslacional E Ingenieria Biomedica. - Instituto Universitario Hospital Italiano de Buenos Aires. Instituto de Medicina Traslacional E Ingenieria Biomedica.; Argentina  
dc.description.fil
Fil: Iturralde, Maria de Los Angeles. Hospital Italiano. Departamento de Informática En Salud.; Argentina  
dc.journal.title
Korean Journal of Anesthesiology  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://ekja.org/journal/view.php?doi=10.4097/kja.21338  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.4097/kja.21338