Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Evento

Inverse allometry: foundations for a bioinspired LVH-prediction model

Bonomini, Maria PaulaIcon ; Ingallina, Fernando; Barone, Valeria; Arini, Pedro DavidIcon
Tipo del evento: Conferencia
Nombre del evento: 5th International Work-conference on the Interplay between Natural and Artificial Computation
Fecha del evento: 10/06/2013
Institución Organizadora: International Work-Conference on the Interplay Between Natural and Artificial Computation;
Título del Libro: Natural and Artificial Models in Computation and Biology
Editorial: Springer
ISBN: 978-3-642-38637-4
Idioma: Inglés
Clasificación temática:
Otras Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información

Resumen

Allometry, in general biology, measures the relative growth of a part in relation to the whole living organism. Left ventricular hypertrophy (LVH) is the heart adaptation to excessive load (systolic or diastolic) that leads to an increase in left ventricular mass, which in turn, raises the electrocardiographic voltages. If this mass increase followed an allometric law, then it would be possible to design a bioinspired model based on the allometric equation to predict LVH. In this work, we first investigated the validity of this hypothesis and then proposed an LVH marker based on the inverse allometry model. Based on clinical data, we compared the allometric behavior of three different ECG markers of LVH. To do this, the allometric fit AECG = δ + β(VM) relating left ventricular mass (estimated from echocardiographic data) and ECG amplitudes (expressed as the Cornell-Voltage, Sokolow and the ECG overall voltage indexes) were compared. Besides, sensitivity and specificity for each index were analyzed. The more sensitive the ECG criteria, the better the allometric fit. Finally, the Receiver Characteristic Curve (ROC) of an allometric model proposed here was computed. In conclusion: The allometric paradigm should be regarded as the way to design new and more sensitive ECG-based LVH markers.
Palabras clave: Receiver operating characteristic curve , Left ventricular hypertrophy , Left ventricular mass , Allometric model , Severe aortic valve stenosis
Ver el registro completo
 
Archivos asociados
Tamaño: 420.9Kb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/158949
DOI: http://dx.doi.org/10.1007/978-3-642-38637-4_36
URL: https://link.springer.com/chapter/10.1007/978-3-642-38637-4_36
Colecciones
Eventos(IAM)
Eventos de INST.ARG.DE MATEMATICAS "ALBERTO CALDERON"
Citación
Inverse allometry: foundations for a bioinspired LVH-prediction model; 5th International Work-conference on the Interplay between Natural and Artificial Computation; Mallorca; España; 2013; 350-357
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES