dc.description.abstract
The combined use of digital holographic microscopy and computer tomography, here named digital holographic micro-tomography, is used to examine the interior of transparent channels. The proposed method is used to identify internal obstacles inside of transparent troughs having slightly different refractive index. The method is based in the acquisition of a set of digital holograms of the specimen whereas it is axially rotated from 0° to 180°. The phase differences retrieved from the obtained holograms are the inputs to a computerised axial tomography procedure. The technique has been numerically modelled in order to find the optimal tomographic conditions and also to realise the minimum difference of refractive index the method could detect. The obtained results show the feasibility of the proposed method for the non-destructive evaluation of transparent micro-objects.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Gmbh  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Digital Holography Microscopy  
dc.subject
Axial Tomography  
dc.subject
Digital Holographic Micro-Tomography  
dc.subject
Non-Destructive Evaluation  
dc.subject.classification
Óptica  
dc.subject.classification
Ciencias Físicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Internal inspection of semi-transparent objects by digital holographic micro-tomography  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2017-04-24T14:48:59Z  
dc.journal.volume
124  
dc.journal.number
18  
dc.journal.pagination
3314-3318  
dc.journal.pais
Alemania  
dc.journal.ciudad
Munich  
dc.description.fil
Fil: Monroy Ramirez, F. A.. Universidad Nacional de Colombia; Colombia  
dc.description.fil
Fil: Dolinko, Andrés Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física de Buenos Aires. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física de Buenos Aires; Argentina  
dc.description.fil
Fil: Garcia Sucerquia, J.. Universidad Nacional de Colombia; Colombia  
dc.journal.title
Optik  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.ijleo.2012.10.062  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0030402612008789