Mostrar el registro sencillo del ítem
dc.contributor.author
Mazivila, Sarmento J.
dc.contributor.author
Lombardi, Juan Manuel
dc.contributor.author
Páscoa, Ricardo N. M. J.
dc.contributor.author
Bortolato, Santiago Andres
dc.contributor.author
Leitão, João M. M.
dc.contributor.author
Silva, Joaquim C. G. Estevez da
dc.date.available
2022-05-02T18:15:19Z
dc.date.issued
2021-02-15
dc.identifier.citation
Mazivila, Sarmento J.; Lombardi, Juan Manuel; Páscoa, Ricardo N. M. J.; Bortolato, Santiago Andres; Leitão, João M. M.; et al.; Three-way calibration using PARAFAC and MCR-ALS with previous synchronization of second-order chromatographic data through a new functional alignment of pure vectors for the quantification in the presence of retention time shifts in peak position and shape; Elsevier Science; Analytica Chimica Acta; 1146; 15-2-2021; 98-108
dc.identifier.issn
0003-2670
dc.identifier.uri
http://hdl.handle.net/11336/156251
dc.description.abstract
In the present contribution is shown the application of the recently developed functional alignment of pure vectors (FAPV) as a proper algorithm to align second-order chromatographic data with severe retention time shifts in peak position and shape. FAPV decomposed a three-way chromatographic data array in their three modes (sample, spectral and elution time vectors), using a basis function to pre-process the non-linear mode (elution time) and then it aligns the functionalized pure vectors and reshapes the transformed vectors into matrices, restoring the trilinearity of second-order chromatographic data. The well-aligned three-way chromatographic data array is then successfully decomposed by advanced chemometric models such as parallel factor analysis (PARAFAC) and multivariate curve resolution − alternating least-squares (MCR-ALS) with the trilinearity constraint. The performance of this innovative analytical strategy based on PARAFAC and MCR-ALS with previous synchronization of data through FAPV algorithm is properly evaluated using real second-order chromatographic data with multiple artifacts, i.e., shifts in peak position and shape for the simultaneous quantification of amoxicillin and potassium clavulanate in commercial medicinal drugs. The present contribution compares some analytical results achieved by: (1) the usual MCR-ALS as a bilinear model applied in augmented data matrix without previous synchronization and with interval correlation optimized shifting (ICOSHIFT) and FAPV and (2) trilinear models using PARAFAC with ICOSHIFT and FAPV and trilinearity constraint in MCR-ALS with FAPV. Available results suggest that these strongly shifted and warped elution time profiles cause for the loss of trilinearity, which can be adequately restored by FAPV algorithm. PARAFAC performed a successful trilinear decomposition of three-way chromatographic data array with law values of relative prediction error (REP) in the order of 1.34?1.42% in both analytes.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
FAPV
dc.subject
MCR-ALS
dc.subject
PARAFAC
dc.subject
SYNCHRONIZATION OF LC-DAD DATA
dc.subject
THREE-WAY CALIBRATION
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Three-way calibration using PARAFAC and MCR-ALS with previous synchronization of second-order chromatographic data through a new functional alignment of pure vectors for the quantification in the presence of retention time shifts in peak position and shape
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2021-12-03T21:36:39Z
dc.journal.volume
1146
dc.journal.pagination
98-108
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Mazivila, Sarmento J.. Universidad de Porto. Facultad de Ciências; Portugal
dc.description.fil
Fil: Lombardi, Juan Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina
dc.description.fil
Fil: Páscoa, Ricardo N. M. J.. Universidad de Porto. Facultad de Ciências; Portugal
dc.description.fil
Fil: Bortolato, Santiago Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina
dc.description.fil
Fil: Leitão, João M. M.. Universidad de Coimbra; Portugal
dc.description.fil
Fil: Silva, Joaquim C. G. Estevez da. Universidad de Porto. Facultad de Ciências; Portugal
dc.journal.title
Analytica Chimica Acta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.aca.2020.12.033
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0003267020312265
Archivos asociados