Artículo

A new parameter for measuring the prediction uncertainty produced by rotational ambiguity in second-order calibration with multivariate curve resolution

Pellegrino Vidal, RocioIcon ; Olivieri, Alejandro CesarIcon
Fecha de publicación: 28/05/2020
Editorial: American Chemical Society
Revista: Analytical Chemistry
ISSN: 0003-2700
e-ISSN: 1520-6882
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Química Analítica

Resumen

Multivariate curve resolution-alternating least-squares (MCR-ALS) is the model of choice when dealing with matrix data that cannot be arranged into a trilinear three-way array, that is, mostly from chromatographic origin with spectral detection. A range of feasible solutions may be found in MCR studies, due to the phenomenon of rotational ambiguity associated with bilinear decompositions of matrices. The application of chemically driven constraints is vital to achieving an adequate solution and minimizing the degree of rotational ambiguity present in the system. However, when studying complex samples, it may not be possible to recover unique solutions, even under the application of proper constraints. In such cases, it is important to be able to assess the propagation of rotation uncertainty to the estimated analyte concentrations, which stems from the existence of a finite range of feasible solutions. In this work, we present a new analytical parameter to estimate the potential uncertainty in analyte prediction brought about by rotational ambiguity, in the form of an associated root-mean-square error, named RMSERA. The proposed parameter comes in the form of a range of values, whose limits are δRA/(12)1/2 and δRA/(3)1/2, with δRA being defined as the difference between the maximum and minimum values of the analyte concentration that would be predicted by the MCR model from its concentration profiles lying in the range of feasible solutions, and corresponding to maximum and minimum area, respectively. We support our proposal on extensive simulations for systems of varying composition, and demonstrate its application on experimental data aimed at the determination of four pollutants in environmental water samples.
Palabras clave: CHEMOMETRICS
Ver el registro completo
 
Archivos asociados
Tamaño: 1.182Mb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/155926
DOI: http://dx.doi.org/10.1021/acs.analchem.0c01395
URL: https://pubs.acs.org/doi/10.1021/acs.analchem.0c01395
Colecciones
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Citación
Pellegrino Vidal, Rocio; Olivieri, Alejandro Cesar; A new parameter for measuring the prediction uncertainty produced by rotational ambiguity in second-order calibration with multivariate curve resolution; American Chemical Society; Analytical Chemistry; 92; 13; 28-5-2020; 9118-9123
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES