Mostrar el registro sencillo del ítem

dc.contributor.author
Dorrego, Camila Iris  
dc.contributor.author
Pellice, Silvana  
dc.contributor.author
Carauni, Ana Lisa  
dc.contributor.author
Chiapella, Luciana Carla  
dc.contributor.author
Dapena, Gimena  
dc.contributor.author
Chamartin, Pablo  
dc.contributor.author
Rocco, Franco Daniel  
dc.contributor.author
Alezzandrini, Arturo Alberto  
dc.date.available
2022-04-04T15:08:53Z  
dc.date.issued
2021-11-05  
dc.identifier.citation
Dorrego, Camila Iris; Pellice, Silvana; Carauni, Ana Lisa; Chiapella, Luciana Carla; Dapena, Gimena; et al.; Asociación entre biomarcadores en tomografía de coherencia óptica y agudeza visual en pacientes con edema macular diabético tratados con antiangiogénicos; Sociedad Argentina de Oftalmología; Archivos Argentinos de Oftalmología; 19; 1; 5-11-2021; 11-23  
dc.identifier.issn
2362-4736  
dc.identifier.uri
http://hdl.handle.net/11336/154272  
dc.description.abstract
Objetivos Evaluar la asociación entre los principales biomarcadores del Edema Macular Diabético (EMD) y la Agudeza Visual (AV), y determinar su importancia como herramienta pronóstica a la hora de iniciar un tratamiento antiangiogénico en cada paciente. Métodos Estudio de cohorte retrospectivo, observacional y longitudinal. Se analizaron 25 escaneos de OCT de 23 pacientes con edema macular diabético (EMD) y se registró la Agudeza Visual Mejor Corregida (AVMC) al inicio, y a los 3, 6 y 9 meses de tratamiento. Las imágenes basales se evaluaron para el tipo predominante de edema macular (Cistoide, espongiforme, con desprendimiento seroso subfoveal o con compromiso traccional); presencia de daño en la retina externa (considerado como cualquier discontinuidad en la Membrana Limitante Externa, Zona Elipsoide y/o Zona de Interdigitación); presencia de desorganización de las Capas Internas de la Retina (DRIL) y cantidad de Puntos Hiperreflectivos (PH) así como del Espesor Macular Central (EMC). Las correlaciones entre cada biomarcador y la ganancia de Agudeza Visual se analizaron utilizando modelos longitudinales de efectos mixtos. Resultados Se incluyeron veinticinco ojos con EMD NAIVE de tratamiento. La AVMC basal se encontraba entre 0,3 y 1,3 en un logaritmo del gráfico visual de ángulo mínimo de resolución (LogMAR). El tipo de edema macular, la presencia de DRIL y el EMC presentaron un efecto estadísticamente significativo sobre la modificación de la AV a lo largo del tiempo (p< 0,001 en todos los casos). Los pacientes con DRIL mostraron menor ganancia de AV en términos LogMAR a los 9 meses que los pacientes sin DRIL, siendo la diferencia estadísticamente significativa (p=0,026), y mostraron menor mejoría en la AV a lo largo de los nueve meses de tratamiento (efecto de interacción p=0,007). Los subtipos de edema con desprendimiento seroso subfoveal, y con componente traccional por otro lado, ganaron menos visión que los pacientes que sólo presentaban edema macular de tipo cistoide. No hubo diferencias estadísticamente significativas entre la presencia de PH y la alteración de las capas retinianas externas con la AV a lo largo del tiempo de tratamiento. Conclusión Es de gran utilidad evaluar el EMC inicial, aunque no de manera aislada, así como es primordial evaluar y considerar la presencia de DRIL como biomarcador pronóstico, que en el presente estudio resultó ser el aquel con mayor potencial como predictor de respuesta clínica en términos de AV.  
dc.description.abstract
Purpose To evaluate the association between the main biomarkers of Diabetic Macular Edema (DME) and the Visual Acuity (VA), and determine its importance as a prognostic tool at time to start an antiangiogenic treatment in each patient. Methods Retrospective, observational and longitudinal cohort study. 25 OCT scans of 23 patients with diabetic macular edema (DME) were analyzed, and the Best Corrected Visual Acuity (BCVA) at baseline and at 3, 6 and 9 months of treatment was registered. Baseline images were evaluated for predominant type of macular edema (cystoid, spongiform, with subfoveal serous detachment, or tractional compromise); presence of outer retinal damage (ORD, considered as any discontinuity in Limiting Extern Membrane, Ellipsoid Zone, and/or Interdigitation Zone); presence of disorganization of the Inner Retinal Layers (DRIL), and Hyperreflective Focis (HF) quantity, as well as Central Macular Thickness (CMT). Correlations between each OCT biomarker and visual acuity gain were analyzed using longitudinal mixed-effects models. Results Twentyfive eyes with NAIVE DME were included. Baseline best-corrected visual acuity (BCVA) was between 0.3 and 1.3 on a logarithm of minimum angle of resolution visual chart (logMAR). Type of macular edema, DRIL presence, and CMT presented a statistically significant effect on the VA modification along the time (p<0,001 in all cases). Patients with DRIL showed worse VA in logMAR terms at 9 months than patients without DRIL, being the difference statistically different (p=0,026), and showed less improvement in VA along the nine months treatment (interaction effect p=0,007). Eyes with subfoveal serous detachment and eyes with tractional component gained less vision than patients with only cystoid macular edema. There were no statistically significant differences between presence of hyperreflective focis, extern retinal layers alteration and VA along the treatment time. Conclusion This study showed that it is useful to assess the initial CMT but not in isolation, and above all the presence of DRIL, which proved to be the tomographic biomarker with the greatest potential as a predictor of clinical response in terms of VA.  
dc.format
application/pdf  
dc.language.iso
spa  
dc.publisher
Sociedad Argentina de Oftalmología  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Edema macular diabético  
dc.subject
Biomarcadores  
dc.subject
OCT  
dc.subject
DRIL  
dc.subject.classification
Oncología  
dc.subject.classification
Medicina Clínica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Asociación entre biomarcadores en tomografía de coherencia óptica y agudeza visual en pacientes con edema macular diabético tratados con antiangiogénicos  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2022-03-16T12:37:15Z  
dc.journal.volume
19  
dc.journal.number
1  
dc.journal.pagination
11-23  
dc.journal.pais
Argentina  
dc.journal.ciudad
Ciudad Autónoma de Buenos Aires  
dc.description.fil
Fil: Dorrego, Camila Iris. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Pellice, Silvana. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Carauni, Ana Lisa. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Chiapella, Luciana Carla. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina  
dc.description.fil
Fil: Dapena, Gimena. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Chamartin, Pablo. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Rocco, Franco Daniel. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Alezzandrini, Arturo Alberto. Universidad de Buenos Aires; Argentina  
dc.journal.title
Archivos Argentinos de Oftalmología  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://archivosoftalmologia.com.ar/index.php/revista/article/view/135/