Artículo

Carotid artery stenting protected with an emboli containment system

Whitlow, Patrick L.; Lylyk, Pedro; Londero, Walter Hugo; Mendiz, Oscar A.; Mathias, Klaus; Jaeger, Horst; Parodi, Juan; Schönholz, Claudio; Milei, JoseIcon
Fecha de publicación: 05/2002
Editorial: Lippincott Williams
Revista: Stroke
ISSN: 0039-2499
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Sistemas Cardíaco y Cardiovascular

Resumen

Background and Purpose—Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. Methods—A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire with a detachable adapter that inflates and deflates the distal temporary occlusion balloon. An aspiration catheter is used to remove trapped emboli after stenting and before occlusion balloon deflation. Results—Seventy-five patients with severe internal carotid artery stenosis were treated with stents deployed with this cerebrovasculature protection system. All 75 patients (100%) had grossly visible particulate material aspirated, and all were treated successfully without major or minor stroke or death at 30 days. Preintervention stenosis was 81 10%, and residual stenosis was 5 7%. Nine patients (12%) had angiographic evidence of thrombus before intervention, but no patient had thrombus or vessel cutoff after the procedure. Four patients (5%) developed transient neurological symptoms during protection balloon occlusion, but symptoms resolved with balloon deflation. The 22 to 667 particles aspirated per patient ranged from 3.6 to 5262 m in maximum diameter (mean, 203 256 m). These particles included fibrous plaque debris, lipid or cholesterol vacuoles, and calcific plaque fragments. Conclusions—Protected carotid stenting was performed successfully and safely in this study early in the experience with cerebrovascular protection devices. Particulate emboli are frequent with stenting, and cerebral protection will likely be necessary to minimize stroke. Randomized trials comparing protected carotid stenting with endarterectomy are warranted. (Stroke. 2002;33:1308-1314.)
Palabras clave: carotid artery diseases , carotid endarterectomy , stents , stroke
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 305.8Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/153068
URL: https://www.ahajournals.org/doi/10.1161/01.STR.0000013947.17575.B3
Colecciones
Articulos(ININCA)
Articulos de INST.DE INVEST.CARDIOLOGICAS (I)
Citación
Whitlow, Patrick L.; Lylyk, Pedro; Londero, Walter Hugo; Mendiz, Oscar A.; Mathias, Klaus; et al.; Carotid artery stenting protected with an emboli containment system; Lippincott Williams; Stroke; 33; 5-2002; 1308-1314
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES