Mostrar el registro sencillo del ítem
dc.contributor.author
Kergaravat, Silvina Vanesa
dc.contributor.author
Fabiano, Silvia Noemi
dc.contributor.author
Soutullo, Adriana Rosa
dc.contributor.author
Hernández, Silvia Raquel
dc.date.available
2022-02-01T11:16:09Z
dc.date.issued
2021-01
dc.identifier.citation
Kergaravat, Silvina Vanesa; Fabiano, Silvia Noemi; Soutullo, Adriana Rosa; Hernández, Silvia Raquel; Comparison of the performance analytical of two glyphosate electrochemical screening methods based on peroxidase enzyme inhibition; Elsevier Science; Microchemical Journal; 160; 1-2021; 1-12
dc.identifier.issn
0026-265X
dc.identifier.uri
http://hdl.handle.net/11336/151043
dc.description.abstract
Glyphosate is the most widely used herbicide in Argentina. The information about this herbicide is controversial as some organisms classify it as dangerous and others as safety. Moreover, the world regulations are very different depending on country. However, many studies had reported its presence in numerous sample types, and also, had demonstrated adverse effects on environmental and human health. In the present work, two electrochemical screening methods based on horseradish peroxidase (HRP) inhibition have been developed for the glyphosate detection. In one of them, the working electrode was built in our laboratory with a graphite-epoxy compound mixture (GEC-E). While the other is based on a biosensor built with commercial screen-printed electrodes (SPE), for which on the working electrode, the HRP enzyme was immobilized by using the affinity reaction between streptavidin and biotin-peroxidase. The detection electrochemical technique was square-wave voltammetry (SWV). When glyphosate inhibits the activity of the soluble or immobilized enzyme, a decrease in the signal is generated at the electrode or biosensor, respectively, and this decrease is proportional to the amount of glyphosate in the sample. The linear range obtained was from 0.16 to 500 ng L-1 glyphosate (R2 = 0.9727) for the soluble HRP-based inhibition method with a limit of detection (LOD) of 0.085 ng L-1. While the range was from 0.08 to 11 μg L-1 glyphosate (R2 = 0.9799) for immobilized HRP-based inhibition method with a LOD of 45 ng L-1. For the screening detection of glyphosate, the decision limits (CCα) and detection capabilities (CCβ) were 115 and 130 ng L-1 for the soluble HRP-based inhibition method and 111 and 122 ng L-1 for biosensor, respectively. Recoveries from 71% to 96% and from 79% to 120% were obtained by two electrochemical methods from groundwater and superficial water with high organic matters spiked with glyphosate, respectively. Therefore, both electrochemical methods allow determining the glyphosate concentration at trace levels in accordance with the strictest European Parliament regulation (100 ng L-1). The soluble HRP-based inhibition method shown better performance than biosensor, but the latter due to its simplicity, stability and portability could be used in the field monitoring or detection of this herbicide in the exposed areas.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
BIOSENSOR
dc.subject
ELECTROCHEMICAL
dc.subject
ENZYME-INHIBITION
dc.subject
GLYPHOSATE
dc.subject
HORSERADISH PEROXIDASE
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Comparison of the performance analytical of two glyphosate electrochemical screening methods based on peroxidase enzyme inhibition
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2021-09-07T14:06:18Z
dc.journal.volume
160
dc.journal.pagination
1-12
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Kergaravat, Silvina Vanesa. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina
dc.description.fil
Fil: Fabiano, Silvia Noemi. Universidad Nacional del Litoral; Argentina
dc.description.fil
Fil: Soutullo, Adriana Rosa. Universidad Nacional del Litoral; Argentina
dc.description.fil
Fil: Hernández, Silvia Raquel. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina
dc.journal.title
Microchemical Journal
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0026265X2032169X
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.microc.2020.105654
Archivos asociados