Mostrar el registro sencillo del ítem
dc.contributor.author
Bonomini, Maria Paula
dc.contributor.author
Villaroel Abrego, Hugo
dc.contributor.author
Garillo, Raúl
dc.date.available
2022-01-31T17:08:34Z
dc.date.issued
2021-05
dc.identifier.citation
Bonomini, Maria Paula; Villaroel Abrego, Hugo; Garillo, Raúl; Spatial variance in the 12-lead ECG and mechanical dyssynchrony; Springer; Journal Of Interventional Cardiac Electrophysiology : An International Journal Of Arrhythmias And Pacing.; 62; 3; 5-2021; 479-485
dc.identifier.issn
1383-875X
dc.identifier.uri
http://hdl.handle.net/11336/150993
dc.description.abstract
Introduction: Electrical transmission disorders have a deleterious effect on cardiac depolarization, resulting in a disorganized ventricular contraction that reduces global mechanical efficiency; this mechanical dyssynchrony can be corrected by cardiac resynchronization therapy. However, despite adjustments in the electrical criteria selection of QRS for the recognition of mechanical dyssynchrony, a significant proportion of patients do not currently respond to this therapy. Purpose: To find if a new predictor of dyssynchrony, the electrocardiogram spatial variance, is a better marker of mechanical dyssynchrony than QRS duration. Methods: Forty-seven electrocardiograms and 47 strain (2D speckle tracking) echocardiograms were prospectively collected simultaneously in consecutive, non-selected patients; the left ventricular mechanical dispersion was measured in all the cases. The electrocardiographic analysis of variance was made with a digital superposition of the electrocardiographic leads and generates different indexes of variance of both QRS complex and repolarization phase. Results: ROC analysis probed that the best area under the curve (AUC) value correlated with left ventricular mechanical dispersion and was obtained combining several spatial variance markers (considering depolarization and repolarization spatial variance together; AUC = 0.97); the same analysis using the QRS duration versus mechanical dispersion showed a significantly lower AUC value (AUC = 0.64). Conclusion: Spatial variance combining depolarization and repolarization markers is a superior predictor of left ventricular mechanical dispersion than QRS duration.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Springer
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
2D SPECKLE TRACKING
dc.subject
MECHANICAL DYSSYNCHRONY
dc.subject
SPATIAL VARIANCE
dc.subject.classification
Ingeniería Médica
dc.subject.classification
Ingeniería Médica
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Spatial variance in the 12-lead ECG and mechanical dyssynchrony
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2021-12-03T21:07:30Z
dc.journal.volume
62
dc.journal.number
3
dc.journal.pagination
479-485
dc.journal.pais
Alemania
dc.journal.ciudad
Berlin
dc.description.fil
Fil: Bonomini, Maria Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Saavedra 15. Instituto Argentino de Matemática Alberto Calderón; Argentina
dc.description.fil
Fil: Villaroel Abrego, Hugo. Universidad del Salvador. Facultad de Medicina; Argentina
dc.description.fil
Fil: Garillo, Raúl. Pontificia Universidad Católica Argentina "Santa María de los Buenos Aires"; Argentina
dc.journal.title
Journal Of Interventional Cardiac Electrophysiology : An International Journal Of Arrhythmias And Pacing.
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1007/s10840-021-00999-9
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://link.springer.com/article/10.1007%2Fs10840-021-00999-9
Archivos asociados