Immunosuppressive drugs (ISDs) are primarily administered following solid organ transplant or for treatment of a variety of autoimmune conditions. Their principal function is to suppress the activity of the immune system; however, the levels must be carefully monitored due to adverse effects of over- or underadministration. A technology for rapid quantitative screening, named coated blade spray (CBS), was directly coupled to a triple quadrupole mass spectrometer (MS/MS) to measure the concentration of ISDs (i.e., cyclosporine A, tacrolimus, everolimus, sirolimus) in whole blood samples. We evaluated the stability of replicate measurements over a 10-day period (precision), assessed linearity and limit of quantification, and performed a method comparison against a validated clinical immunoassay (Abbott ARCHITECT). Total interday variation of less than 5% for all target compounds at three different concentrations was achieved. The sensitivity of the method was determined as 0.25, 1, 1, and 2.5 ng/mL for everolimus, sirolimus, tacrolimus, and cyclosporine A, respectively. The concentrations of three immunosuppressive drugs in 284 patient samples (i.e., ~ 95 samples of cyclosporine A, tacrolimus, or sirolimus) obtained using the CBS-MS/MS methodology were compared with concentrations previously quantified on an Abbott ARCHITECT immunoassay system. Our analysis demonstrated significant statistical similarities between both methods. The results demonstrate that CBS-MS/MS is a suitable alternative to conventional methodologies for monitoring of ISDs from whole blood in a clinical setting.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Articulos de SEDE CENTRAL
Citación
Rickert, Daniel A.; Gómez Ríos, Germán A.; Nazdrajic, Emir; Tascon, Marcos; Kulasingam, Vathany; et al.; Evaluation of a coated blade spray-tandem mass spectrometry assay as a new tool for the determination of immunosuppressive drugs in whole blood; Springer Heidelberg; Analytical and Bioanalytical Chemistry; 412; 21; 8-2020; 5067-5076
Compartir
Altmétricas