Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Blood-pressure–waveform monitoring without interruptions due to changes in arterial compliance: The use of the vibrational and volume-clamp methods

Casal, LeonardoIcon ; Mazzadi, Alejandro Noel
Fecha de publicación: 11/2021
Editorial: Elsevier
Revista: Medical Engineering & Physics
ISSN: 1350-4533
e-ISSN: 1873-4030
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Ingeniería Médica

Resumen

The arterial–blood-pressure (ABP) waveform can be monitored by the volume-clamp method. The photoplethysmography (PPG) signal is measured and clamped at maximum arterial compliance (PPGcmax) by controlling the external pressure (EP) with a cuff. PPGcmax is determined by the volume-oscillometric method though ABP measurement is regularly interrupted. To overcome this drawback, the vibrational method superimposes high-frequency vibrations on EP and measures the PPG response to estimate the “vibrational” compliance (Cv) and the PPGcmax. This method, though, has never been validated or implemented simultaneously with the volume-clamp method because the control has always been unstable. We implemented a custom-made device with a novel control system, monitoring stability and adapting the gain at high frequencies, plus lower-amplitude EP vibrations. We compared, in eleven volunteers, the EP at PPGcmax determined by the volume-oscillometric and the vibrational methods. Both exhibited a good linear correlation (r2 >0.92) and Bland-Altman agreement (95% confidence interval <15 mmHg). Moreover, in three volunteers, the vibrational and volume-clamp methods were implemented together while experimentally changing the ABP and/or Cv without manifesting control-system instability. Cv measured with the vibrational method could be used by the volume-clamp method to measure the ABP waveform without any interruptions due to changes in arterial compliance.
Palabras clave: ARTERIAL BLOOD PRESSURE , ARTERIAL COMPLIANCE , VIBRATIONAL METHOD , VOLUME-CLAMP METHOD
Ver el registro completo
 
Archivos asociados
Tamaño: 1.671Mb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/149023
URL: https://www.sciencedirect.com/science/article/abs/pii/S1350453321001077
DOI: http://dx.doi.org/10.1016/j.medengphy.2021.09.006
Colecciones
Articulos(OCA PQUE. CENTENARIO)
Articulos de OFICINA DE COORDINACION ADMINISTRATIVA PQUE. CENTENARIO
Citación
Casal, Leonardo; Mazzadi, Alejandro Noel; Blood-pressure–waveform monitoring without interruptions due to changes in arterial compliance: The use of the vibrational and volume-clamp methods; Elsevier; Medical Engineering & Physics; 97; 11-2021; 25-31
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES