Mostrar el registro sencillo del ítem

dc.contributor.author
Floriano, Alan  
dc.contributor.author
Delisle Rodriguez, Denis  
dc.contributor.author
Diez, Pablo Federico  
dc.contributor.author
Bastos Filho, Teodiano Freire  
dc.date.available
2021-12-06T19:18:42Z  
dc.date.issued
2020-02  
dc.identifier.citation
Floriano, Alan; Delisle Rodriguez, Denis; Diez, Pablo Federico; Bastos Filho, Teodiano Freire; Assessment of high-frequency steady-state visual evoked potentials from below-the-hairline areas for a brain-computer interface based on Depth-of-Field; Elsevier Ireland; Computer Methods And Programs In Biomedicine; 184; 2-2020; 1-6  
dc.identifier.issn
0169-2607  
dc.identifier.uri
http://hdl.handle.net/11336/148328  
dc.description.abstract
Background and Objective: Recently, a promising Brain-Computer Interface based on Steady-State Visual Evoked Potential (SSVEP-BCI) was proposed, which composed of two stimuli presented together in the center of the subject's field of view, but at different depth planes (Depth-of-Field setup). Thus, users were easily able to select one of them by shifting their eye focus. However, in that work, EEG signals were collected through electrodes placed on occipital and parietal regions (hair-covered areas), which demanded a long preparation time. Also, that work used low-frequency stimuli, which can produce visual fatigue and increase the risk of photosensitive epileptic seizures. In order to improve the practicality and visual comfort, this work proposes a BCI based on Depth-of-Field using the high-frequency SSVEP response measured from below-the-hairline areas (behind-the-ears). Methods: Two high-frequency stimuli (31 Hz and 32 Hz) were used in a Depth-of-Field setup to study the SSVEP response from behind-the-ears (TP9 and TP10). Multivariate Spectral F-test (MSFT) method was used to verify the elicited response. Afterwards, a BCI was proposed to command a mobile robot in a virtual reality environment. The commands were recognized through Temporally Local Multivariate Synchronization Index (TMSI) method. Results: The data analysis reveal that the focused stimuli elicit distinguishable SSVEP response when measured from hairless areas, in spite of the fact that the non-focused stimulus is also present in the field of view. Also, our BCI shows a satisfactory result, reaching average accuracy of 91.6% and Information Transfer Rate (ITR) of 5.3 bits/min. Conclusion: These findings contribute to the development of more safe and practical BCI.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Ireland  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by/2.5/ar/  
dc.subject
BRAIN-COMPUTER INTERFACE  
dc.subject
DEPTH-OF-FIELD  
dc.subject
EEG  
dc.subject
HAIRLESS AREAS  
dc.subject.classification
Otras Ingeniería Médica  
dc.subject.classification
Ingeniería Médica  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Assessment of high-frequency steady-state visual evoked potentials from below-the-hairline areas for a brain-computer interface based on Depth-of-Field  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2021-11-09T18:57:01Z  
dc.identifier.eissn
1872-7565  
dc.journal.volume
184  
dc.journal.pagination
1-6  
dc.journal.pais
Irlanda  
dc.journal.ciudad
Shannon  
dc.description.fil
Fil: Floriano, Alan. Universidade Federal do Espírito Santo; Brasil  
dc.description.fil
Fil: Delisle Rodriguez, Denis. Universidade Federal do Espírito Santo; Brasil  
dc.description.fil
Fil: Diez, Pablo Federico. Universidad Nacional de San Juan. Facultad de Ingeniería. Departamento de Electrónica y Automática. Gabinete de Tecnología Médica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Juan; Argentina  
dc.description.fil
Fil: Bastos Filho, Teodiano Freire. Universidade Federal do Espírito Santo; Brasil  
dc.journal.title
Computer Methods And Programs In Biomedicine  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0169260719314713  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.cmpb.2019.105271