Study of the energy consumption of a massive free-running building in the Argentinean northwest through monitoring and thermal simulation

Flores Larsen, Silvana ElinorIcon ; Filippin, Maria CelinaIcon ; González, Silvina MarianaIcon
Fecha de publicación: 04/2012
Editorial: Elsevier Science
Revista: Energy And Buildings
ISSN: 0378-7788
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ingenierías y Tecnologías

Resumen

The investigation presented in this paper has three main objectives. The first one is to study, through a case study, if it is possible to acceptably predict the energy consumption of a massive residential free-running building, when the exact behavior of the occupants is unknown or actual indoor conditions are not monitored, assuming standard use and occupation schedules, for the dry climate of the Argentinean Northwest. The second objective of the paper is to detect the possible causes of differences between actual and predicted energy consumption through an exhaustive thermal monitoring and occupant's behavior, in order to obtain an improved model of the building giving more accurate predictions of the energy consumption. The third objective is to analyze the effect on the annual energy consumption of changing the massive envelope by a lightweight one. The comparison of real and simulated consumptions under comfort conditions defined by ASHRAE Standard 55 shows that simulations overestimated the energy consumption for heating and cooling. The main causes were detected from the experimental monitoring, indicating a lower use of the air conditioning equipment than the supposed initially. Simulations were improved to consider actual use and occupation conditions. Finally, an annual simulation of the improved model performed by changing the envelope material to a lightweight one showed that energy consumption for heating was increased, while energy consumption for cooling was decreased. In an annual balance, the massive walls are preferable over lightweight ones in arid sunny climates as in the Argentinean Northwest, giving energy savings of around 25%.
Palabras clave: Energy Consumption , Thermal Simulation , Energyplus , User Behaviour
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 904.1Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Atribución-NoComercial-SinDerivadas 2.5 Argentina (CC BY-NC-ND 2.5 AR)
Identificadores
URI: http://hdl.handle.net/11336/14534
DOI: http://dx.doi.org/10.1016/j.enbuild.2011.12.004
URL: http://www.sciencedirect.com/science/article/pii/S0378778811005998
Colecciones
Articulos(INENCO)
Articulos de INST.DE INVEST.EN ENERGIA NO CONVENCIONAL
Citación
Flores Larsen, Silvana Elinor; Filippin, Maria Celina; González, Silvina Mariana; Study of the energy consumption of a massive free-running building in the Argentinean northwest through monitoring and thermal simulation; Elsevier Science; Energy And Buildings; 47; 4-2012; 341-352
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES