Mostrar el registro sencillo del ítem

dc.contributor.author
Alison Hernandez, Paula  
dc.contributor.author
Ferndez Boderueau, Enrique  
dc.contributor.author
Moyano, Teresa Azucena  
dc.contributor.author
Arguelles, Sandra  
dc.contributor.author
Solla, Catalina  
dc.contributor.author
Mattea, Facundo  
dc.contributor.author
Valente, Mauro Andres  
dc.contributor.author
Martín, Gabriela  
dc.date.available
2021-10-27T13:45:42Z  
dc.date.issued
2020-10-05  
dc.identifier.citation
Alison Hernandez, Paula; Ferndez Boderueau, Enrique; Moyano, Teresa Azucena; Arguelles, Sandra; Solla, Catalina; et al.; Obturación endodóntica de las raíces mesiales de molares inferiores con sellador Bio-C Sealer y AHPlus; Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Methodo; 5; 4; 5-10-2020; 129-135  
dc.identifier.issn
2545-8302  
dc.identifier.uri
http://hdl.handle.net/11336/145215  
dc.description.abstract
La obturación del conducto radicular se realiza con conos de gutapercha y un sellador endodóntico, el cual rellena los espacios entre la pared dentinaria y el material obturador; y las irregularidades del conducto radicular. El sellador Bio-C Sealer es un cemento biocerámico con propiedades bioactivas y AH Plus es un cemento a base de resina. La hipótesis del presente estudio fue que el sellador Bio-C Sealer ocupa mayor volumen y superficie que el sellador AH Plus. Objetivo: Comparar el uso del sellador Bio-C Sealer con el sellador AH Plus en la obturación de conductos mesiales de molares inferiores. Materiales y métodos: Se seleccionaron 40 conductos (20 mesio-vestibulares y 20 mesio-linguales) de 20 raíces mesiales de molares inferiores permanentes. Los conductos fueron instrumentados con limas Wave One Gold Small (Dentsply, Maillefer) y WaneOne Gold Primary e irrigados con hipoclorito de sodio. Para la obturación, la muestra se dividió en dos grupos de 20 conductos cada uno, de acuerdo al sellador endodóntico utilizado. Grupo A: sellador AH Plus (Dentsply, Maillefer) y Grupo B: sellador Bio-C Sealer (Angelus). Finalizada la obturación, se utilizó la microtomografía computada (micro-CT) de alta resolución con un detector tipo flat-panel certificado de la compañía Varian R (USA) modelo PaxScan 2020+ para obtener 180 cortes tomográficos de cada muestra. Luego se reconstruyó la imagen 3D de la muestra utilizando algoritmos específicos dedicados en el software MatLab (MathWorks, USA), y con desarrollos propios del equipo de investigación en lenguaje Python en las instalaciones del Laboratorio de Física Aplicada a la Medicina (FaMAF). Los datos obtenidos fueron analizados estadísticamente mediante el test de Mann Whitney. Resultados: No se encontraron diferencias significativas en el volumen de obturación entre las muestras tratadas con sellador AH Plus y sellador Bio C- Sealer (p>0,05). Respecto al volumen de espacios vacíos, la frecuencia de casos en los cuales pudieron detectarse volúmenes de vacíos mensurables (≥ 0,01 mm3) fue del 15%; registrándose 2 en el grupo BIO-C sealer (5%) y 4 en AH Plus (10%). Conclusión: Bajo las condiciones de este estudio, se puede concluir que ambos selladores AH Plus y Bio-C Sealer resultaron adecuados para la obturación de los conductos mesio-vestibulares y mesio-linguales de molares inferiores. Sin embargo, el volumen de espacios vacíos fue menor cuando se usó el sellador biocerámico Bio-C Sealer.  
dc.description.abstract
Root canal obturations are usually performed with guttapercha cones and an endodontic sealer, filling the space between the dentinal wall and filling material, and the irregularities of the root canal. Bio-C Sealer is a bioceramic and bioactive sealer, whereas AH Plus is a resin endodontic sealer. The hypothesis of the present study was that Bio-C sealer occupies greater volume and surface than AH plus. OBJECTIVE: To compare the use of the Bio-C Sealer and AH Plus in the filling of mesial root canals of mandibular molars. MATERIALS AND METHODS: Forty root canals (20 mesio-buccal and 20 mesio-lingual) of 20 mesial roots of mandibular permanent molars were selected. The mesial root canals were instrumented with Wave One Gold Small files (Dentsply, Maillefer) and Wave One Gold Primary files and irrigated with sodium hypochlorite. After the instrumentation, root canals were irrigated with EDTA, as final irrigation, to induce sealer penetration through dentinal tubules. For the obturation, the samples were divided into two groups according to the used endodontic sealer. Group A: AH plus sealer (Dentsply, Maillefer) and Group B: BioC Sealer bioceramic sealer (Angelus). Afterwards, a high-resolution micro-tomography (micro-CT), with a certified flat-panel detector from Varian R (USA), model PaxScan 2020+ was used to obtain 180 tomographic projections of each sample. Then, 3D sample images were reconstructed by using specific dedicated algorithms in MatLab (MathWorks, USA), and specific coding developed in Python, at LIIFAMIRx – National University of Cordoba. Recorded data were statistically analyzed by the Mann Whitney Test. RESULTS: No significant differences were found in the sealing volume between the AH Plus and the BioC Sealer (p>0,05). A higher index of empty spaces was observed in the endodontic filling when AH Plus was used compared to Bio-C Sealer. Empty spaces were found in 15% of root canals; 10% for AH Plus and 5% for Bio-C sealer. CONCLUSION: Within the limitations of the current study, it can be concluded that both sealers, AH Plus and Bio-C Sealer, were adequate to fill mesial- buccal and mesial-lingual root canals of mandibular molars. Although, the volume of empty spaces was lower when Bio-C Sealer bioceramic was used.  
dc.format
application/pdf  
dc.language.iso
spa  
dc.publisher
Universidad Católica de Córdoba. Facultad de Ciencias de la Salud  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Sellador endodóntico  
dc.subject
obturación del conducto radicular  
dc.subject
diente molar  
dc.subject.classification
Otras Ciencias Físicas  
dc.subject.classification
Ciencias Físicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.subject.classification
Odontología, Medicina y Cirugía Oral  
dc.subject.classification
Medicina Clínica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Obturación endodóntica de las raíces mesiales de molares inferiores con sellador Bio-C Sealer y AHPlus  
dc.title
Endodontic obturation of mesial roots of mandibular molars with Bio-C Sealer and AHPlus  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2021-09-06T16:04:20Z  
dc.journal.volume
5  
dc.journal.number
4  
dc.journal.pagination
129-135  
dc.journal.pais
Argentina  
dc.journal.ciudad
Córdoba  
dc.description.fil
Fil: Alison Hernandez, Paula. Universidad Católica de Córdoba; Argentina  
dc.description.fil
Fil: Ferndez Boderueau, Enrique. Universidad Nacional de Córdoba; Argentina  
dc.description.fil
Fil: Moyano, Teresa Azucena. Universidad Nacional de Córdoba; Argentina. Universidad Católica de Córdoba; Argentina  
dc.description.fil
Fil: Arguelles, Sandra. Universidad Católica de Córdoba; Argentina  
dc.description.fil
Fil: Solla, Catalina. Universidad Católica de Córdoba; Argentina  
dc.description.fil
Fil: Mattea, Facundo. Universidad Nacional de Córdoba. Instituto de Investigación y Desarrollo en Ingeniería de Procesos y Química Aplicada. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigación y Desarrollo en Ingeniería de Procesos y Química Aplicada; Argentina  
dc.description.fil
Fil: Valente, Mauro Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina  
dc.description.fil
Fil: Martín, Gabriela. Universidad Católica de Córdoba; Argentina  
dc.journal.title
Methodo  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://methodo.ucc.edu.ar/index.php/methodo/article/view/209