Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Inmunoensayo multiplex para el diagnóstico simultáneo de Diabetes Mellitus Autoinmune y Enfermedad Celíaca

Título: Multiplex immunoassay for simultaneous diagnostic of autoimmune diabetes mellitus and celiac disease
Bombicino, Silvina SoniaIcon ; Sabljic, Adriana Victoria; Faccinetti, Natalia InesIcon ; Guerra, Luciano LucasIcon ; Marfía, Juan IgnacioIcon ; Masci, IvanaIcon ; Trabucchi, AldanaIcon ; Poskus, EdgardoIcon ; Valdez, Silvina NoemiIcon
Fecha de publicación: 05/2020
Editorial: Sociedad Argentina de Diabetes
Revista: Revista de la Sociedad Argentina de Diabetes
ISSN: 0325-5247
e-ISSN: 2346-9420
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias de la Salud

Resumen

 
Introducción: la diabetes mellitus autoinmune (DMA) y la enfermedad celíaca (EC) son enfermedades crónicas, poligénicas y multifactoriales vinculadas con la disfunción del sistema inmune. Dado que es frecuente que un mismo paciente presente ambas patologías, la detección simultánea de los marcadores de autoinmunidad de DMA y EC sería una estrategia racional para mejorar el diagnóstico. Objetivos: desarrollar un inmunoensayo basado en citometría de flujo (FloCMIA multiplex) para la detección simultánea y discriminativa de marcadores de DMA (GADA e IA-2A) y de EC (tTgA). Materiales y métodos: las muestras analizadas consistieron en sueros provenientes de 35 individuos controles normales y 21 pacientes con diabetes mellitus tipo 1 (DM1). Se empleó un modelo de ?doble paratope? incubando los sueros con una mezcla de microesferas de diferente fluorescencia interna, cada una adsorbida con un autoantígeno: TrxGAD, TrxIA-2 o H6-tTg, y una mezcla de dichos autoantígenos biotinilados. Los inmunocomplejos se detectaron con estreptavidina-ficoeritrina y se adquirió en un citómetro de flujo. Resultados: FloCMIA multiplex detectó GADA en el 76,2% de los pacientes e IA-2A en el 52,38% (sensibilidad analítica: 88,24 y 56,25% respectivamente,y especificidad: 85,71%) y tTgA en el 42,86% (sensibilidad analítica: 50,0%, y especificidad: 80,0%). Estos resultados se contrastaron con el ensayo de unión de radioligando para GADA e IA-2A y se detectaron 80,95 y 76,19% de los sueros respectivamente (especificidad: 100%), y con un ELISA para tTgA se detectó un 38,1% (especificidad: 97,1%). Conclusiones: FloCMIA multiplex permitió detectar y discriminar GADA, IA-2A y/o tTgA, -en un único acto analítico- en sueros de pacientes con DMA y/o EC. El novedoso inmunoensayo desarrollado simplifica el screening de la población a gran escala.
 
ntroduction: autoimmune diabetes mellitus (ADM) and celiac disease (CD) are chronic, polygenic and multifactorial diseases associated with immune system dysfunction. As it is frequent that a patient presents both pathologies, the simultaneous detection of autoimmunity markers of ADM and CD would be a rational strategy to improve the diagnosis. Objectives: to develop an immunoassay based on Flow Cytometry (FloCMIA multiplex) for the simultaneous and discriminative detection of markers for ADM (GADA and IA-2A) and CD (tTgA). Materials and methods: thirty five serum samples of control individuals and 21 type 1 diabetes mellitus (T1DM) patients were assayed. A “double bridge” model was used for the assay, incubating the serum samples with a mixture of microspheres containing different amount of internal fluorescence, each one adsorbed with an autoantigen: TrxGAD, TrxIA-2 or H6 -tTg, and a mixture of the same biotinilated autoantigens. The immunocomplexes were detected using streptavidinphycoerytrin and then acquired in a flow cytometer. Results: FloCMIA multiplex detected GADA in 76.2% of the patients; IA-2A in 52.38% (analytical sensitivity: 88.24% and 56.25% respectively, and specificity: 85.71%) and tTgA in 42.86% (analytical sensitivity: 50.0%, and specificity: 80.0%). These results were compared with the radioligand binding assay for GADA and IA-2A, detecting 80.95% and 76.19% of the serum samples respectively (100% specificity), and with an ELISA for tTgA detecting 38.1% (97.1% specificity). Conclusions: FloCMIA multiplex allowed detecting and discriminating GADA, IA-2A and/or tTgA, -in a single assay- in serum samples of ADM and/or CD. The novel developed immunoassay simplifies the screening of the large scale population.
 
Palabras clave: Diabetes Mellitus Autoinmune , Enfermedad Celíaca , Autoanticuerpos , Inmunoensayo Multiplex
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 288.9Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/143162
URL: https://www.revistasad.com/index.php/diabetes/article/view/174
Colecciones
Articulos(IDEHU)
Articulos de INST.DE EST.DE LA INMUNIDAD HUMORAL PROF.R.A.MARGNI
Citación
Bombicino, Silvina Sonia; Sabljic, Adriana Victoria; Faccinetti, Natalia Ines; Guerra, Luciano Lucas; Marfía, Juan Ignacio; et al.; Inmunoensayo multiplex para el diagnóstico simultáneo de Diabetes Mellitus Autoinmune y Enfermedad Celíaca; Sociedad Argentina de Diabetes; Revista de la Sociedad Argentina de Diabetes; 54; 1; 5-2020; 3-14
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES