Mostrar el registro sencillo del ítem
dc.contributor.author
Fritz, Mariana
dc.contributor.author
Rinaldi, Gustavo Juan
dc.date.available
2021-10-07T14:42:31Z
dc.date.issued
2007-07-18
dc.identifier.citation
Fritz, Mariana; Rinaldi, Gustavo Juan; Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat; BioMed Central; Journal Of Biomedical Science; 14; 6; 18-7-2007; 757-765
dc.identifier.issn
1021-7770
dc.identifier.uri
http://hdl.handle.net/11336/143122
dc.description.abstract
Systolic blood pressure (SBP) is frequently measured in rats by the tail cuff method, which usually comprises pulse/flow disappearance and reappearance during cuff inflation (Inf) and deflation (Def), separated by an interval between cycles (IBC). Although Def values are habitually used to estimate SBP, in 58 Wistar rats we found (Def-Inf) to be -6 ± 1 mmHg, indicating that Def < Inf in most cases. When the IBC was lengthened to 2 min, (Def-Inf) was increased to -17 ± 2 mmHg, indicating the probable accumulation of a vasodilating metabolite. This increase of (Def-Inf) was prevented by papaverine, indicating its relation to smooth muscle contractility. Adrenergic blockade did not prevent the increase of (Def-Inf), but pretreatment with L-NAME decreased it to -5 ± 2 mmHg (p < 0.05). Simultaneous measurement of SBP by tail-cuff method and carotid cannulation revealed that the Inf value was the most accurate estimation of intravascular SBP. We conclude that: (1) the Inf value should be taken as representative of SBP, since depending on the duration of suprasystolic compression the Def value can underestimate it, and (2) nitric oxide accumulation due to flow deprivation was the main cause of SBP underestimation by Def values. © 2007 National Science Council.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
BioMed Central
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by/2.5/ar/
dc.subject
L-NAME
dc.subject
NITRIC OXIDE
dc.subject
SYSTOLIC BLOOD PRESSURE
dc.subject
TAIL-CUFF METHOD
dc.subject.classification
Fisiología
dc.subject.classification
Medicina Básica
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-07-20T20:19:52Z
dc.identifier.eissn
1423-0127
dc.journal.volume
14
dc.journal.number
6
dc.journal.pagination
757-765
dc.journal.pais
Reino Unido
dc.journal.ciudad
Londres
dc.description.fil
Fil: Fritz, Mariana. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Departamento de Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
dc.description.fil
Fil: Rinaldi, Gustavo Juan. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Departamento de Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Cardiovasculares "Dr. Horacio Eugenio Cingolani". Universidad Nacional de La Plata. Facultad de Ciencias Médicas. Centro de Investigaciones Cardiovasculares "Dr. Horacio Eugenio Cingolani"; Argentina
dc.journal.title
Journal Of Biomedical Science
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s11373-007-9191-1
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://link.springer.com/article/10.1007%2Fs11373-007-9191-1
Archivos asociados