Mostrar el registro sencillo del ítem
dc.contributor.author
Larrateguy, Luis Darío
dc.contributor.author
Pais, Carlos Marcelo
dc.contributor.author
Larrateguy, Luis Ignacio
dc.contributor.author
Larrateguy, Santiago Darío
dc.contributor.author
Schlotthauer, Gaston
dc.date.available
2021-10-06T18:09:37Z
dc.date.issued
2020-06
dc.identifier.citation
Larrateguy, Luis Darío; Pais, Carlos Marcelo; Larrateguy, Luis Ignacio; Larrateguy, Santiago Darío; Schlotthauer, Gaston; Simplified sleep resistance test for daytime sleepiness detection; Brazilian Association of Sleep and Latin American Federation of Sleep Societies; Sleep Science; 14; 2; 6-2020; 164-168
dc.identifier.issn
1984-0063
dc.identifier.uri
http://hdl.handle.net/11336/142919
dc.description.abstract
Objectives: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of a simple test of simplify the detection of daytime sleepiness compared with the OSLER test. Material and Methods: In the new test, during 20 minute subjects were asked to pass a finger by a groove in response to a light emitting diode, inside dark glasses, which was lit for 1s in every three, with headphones that reduce the ambient noise and was compared with the OSLER test on each subject in random order. Results: The proposed method showed a sensitivity of 100% and a specificity of 61%, with a positive predictive value of 67% and negative predictive value of 100% when compared with the OSLER test. The value of area under the ROC curve was 0.81 (0.62-0.99), p=0.013. In a Bland-Altman plot, most of the latency times differences are in the 95% agreement interval (p=0.05). In addition, the confidence interval of the mean and most of the positive results are above the zero line. The Cohens Kappa coefficient obtained is 0.58 (95% CI 0.29-0.88). Conclusion: In this sample of patients, the proposed method detects EDS in a similar way as OSLER test and can be performed in different environments without requiring special infrastructure or expert personnel.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Brazilian Association of Sleep and Latin American Federation of Sleep Societies
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
SLEEP APNEA SYNDROMES
dc.subject
SLEEPINESS
dc.subject
WAKEFULNESS
dc.subject.classification
Ingeniería Médica
dc.subject.classification
Ingeniería Médica
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Simplified sleep resistance test for daytime sleepiness detection
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2021-09-07T14:02:25Z
dc.journal.volume
14
dc.journal.number
2
dc.journal.pagination
164-168
dc.journal.pais
Brasil
dc.journal.ciudad
San Pablo
dc.description.fil
Fil: Larrateguy, Luis Darío. Centro Privado de Medicina Respiratoria; Argentina
dc.description.fil
Fil: Pais, Carlos Marcelo. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
dc.description.fil
Fil: Larrateguy, Luis Ignacio. Centro Privado de Medicina Respiratoria; Argentina
dc.description.fil
Fil: Larrateguy, Santiago Darío. Centro Privado de Medicina Respiratoria; Argentina
dc.description.fil
Fil: Schlotthauer, Gaston. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería. Departamento de Matemática e Informática. Laboratorio de Señales y Dinámicas no Lineales; Argentina
dc.journal.title
Sleep Science
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://sleepscience.org.br/export-pdf/2802/aop408.pdf
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.5935/1984-0063.20200046
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8340892/
Archivos asociados