Mostrar el registro sencillo del ítem

dc.contributor.author
Cruz Sotolongo, Annaly  
dc.contributor.author
Messina, María Mercedes  
dc.contributor.author
Ibañez, Francisco Javier  
dc.contributor.author
Wuilloud, Rodolfo German  
dc.date.available
2021-09-22T11:17:25Z  
dc.date.issued
2020-04-01  
dc.identifier.citation
Cruz Sotolongo, Annaly; Messina, María Mercedes; Ibañez, Francisco Javier; Wuilloud, Rodolfo German; Hybrid ionic liquid-3D graphene-Ni foam for on-line preconcentration and separation of Hg species in water with atomic fluorescence spectrometry detection; Elsevier; Talanta; 210; 01-4-2020; 1-8  
dc.identifier.issn
0039-9140  
dc.identifier.uri
http://hdl.handle.net/11336/141086  
dc.description.abstract
A preconcentration method based on a novel hybrid sorption nanomaterial consisting in a 3D graphene-Ni foam functionalized with an ionic liquid (IL) was developed for Hg species determination. The capability of different phosphonium-ionic liquids (PILs) to functionalize the hybrid material and form ion-pairs with Hg(II) chlorocomplex was evaluated. A comparative study with PILs containing the trihexyl(tetradecyl)phosphonium cation but different anions (dicyanamide and decanoate) and trihexyl(tetradecyl)phosphonium chloride was performed. Inorganic Hg (InHg) species was selectively retained forming a chlorocomplex (HgCl4 2−) followed by its retention in a column filled with the IL-3D graphene-Ni foam material implemented in an on-line micro solid phase extraction system (μSPE). The elution of Hg from the column was performed with SnCl2, which was also used as reducing agent for subsequent detection by cold vapor generation atomic fluorescence spectrometry (CV-AFS). Organic mercury species (OrgHg) were not retained on the sorption material of the column. The effect of several parameters determining the efficiency of the preconcentration and detection system (sample loading and elution flow rate, sample volume, instrumental conditions, etc.) was investigated. A sensitivity enhancement factor (EF) of 180 was achieved for InHg. The detection limit obtained after the preconcentration of 100 mL of sample was 3.6 ng L−1 of InHg. The relative standard deviation (RSD) was 4.1% (at 1 μg L−1 InHg and n = 10) calculated from the peak height of the absorbance signals (Gaussian form and reproducible peaks). This work reports the first application of the IL-3D graphene-Ni foam in an on-line μSPE preconcentration system for the speciation analysis of Hg in mineral, tap, and river water samples.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
GRAPHENE  
dc.subject
HYBRID NANOMATERIAL  
dc.subject
IONIC LIQUID  
dc.subject
MERCURY  
dc.subject
PRECONCENTRATION  
dc.subject
SPECIATION  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Hybrid ionic liquid-3D graphene-Ni foam for on-line preconcentration and separation of Hg species in water with atomic fluorescence spectrometry detection  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2021-08-25T19:26:57Z  
dc.journal.volume
210  
dc.journal.pagination
1-8  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Cruz Sotolongo, Annaly. Universidad Nacional de Cuyo. Facultad de Ciencias Exactas y Naturales. Laboratorio de Química Analítica para Investigación y Desarrollo; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto Interdisciplinario de Ciencias Básicas. - Universidad Nacional de Cuyo. Instituto Interdisciplinario de Ciencias Básicas; Argentina  
dc.description.fil
Fil: Messina, María Mercedes. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina  
dc.description.fil
Fil: Ibañez, Francisco Javier. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina  
dc.description.fil
Fil: Wuilloud, Rodolfo German. Universidad Nacional de Cuyo. Facultad de Ciencias Exactas y Naturales. Laboratorio de Química Analítica para Investigación y Desarrollo; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto Interdisciplinario de Ciencias Básicas. - Universidad Nacional de Cuyo. Instituto Interdisciplinario de Ciencias Básicas; Argentina  
dc.journal.title
Talanta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2019.120614  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914019312470?via%3Dihub