dc.identifier.citation
Cruz Sotolongo, Annaly; Messina, María Mercedes; Ibañez, Francisco Javier; Wuilloud, Rodolfo German; Hybrid ionic liquid-3D graphene-Ni foam for on-line preconcentration and separation of Hg species in water with atomic fluorescence spectrometry detection; Elsevier; Talanta; 210; 01-4-2020; 1-8
dc.identifier.issn
0039-9140
dc.identifier.uri
http://hdl.handle.net/11336/141086
dc.description.abstract
A preconcentration method based on a novel hybrid sorption nanomaterial consisting in a 3D graphene-Ni foam functionalized with an ionic liquid (IL) was developed for Hg species determination. The capability of different phosphonium-ionic liquids (PILs) to functionalize the hybrid material and form ion-pairs with Hg(II) chlorocomplex was evaluated. A comparative study with PILs containing the trihexyl(tetradecyl)phosphonium cation but different anions (dicyanamide and decanoate) and trihexyl(tetradecyl)phosphonium chloride was performed. Inorganic Hg (InHg) species was selectively retained forming a chlorocomplex (HgCl4 2−) followed by its retention in a column filled with the IL-3D graphene-Ni foam material implemented in an on-line micro solid phase extraction system (μSPE). The elution of Hg from the column was performed with SnCl2, which was also used as reducing agent for subsequent detection by cold vapor generation atomic fluorescence spectrometry (CV-AFS). Organic mercury species (OrgHg) were not retained on the sorption material of the column. The effect of several parameters determining the efficiency of the preconcentration and detection system (sample loading and elution flow rate, sample volume, instrumental conditions, etc.) was investigated. A sensitivity enhancement factor (EF) of 180 was achieved for InHg. The detection limit obtained after the preconcentration of 100 mL of sample was 3.6 ng L−1 of InHg. The relative standard deviation (RSD) was 4.1% (at 1 μg L−1 InHg and n = 10) calculated from the peak height of the absorbance signals (Gaussian form and reproducible peaks). This work reports the first application of the IL-3D graphene-Ni foam in an on-line μSPE preconcentration system for the speciation analysis of Hg in mineral, tap, and river water samples.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
GRAPHENE
dc.subject
HYBRID NANOMATERIAL
dc.subject
IONIC LIQUID
dc.subject
MERCURY
dc.subject
PRECONCENTRATION
dc.subject
SPECIATION
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Hybrid ionic liquid-3D graphene-Ni foam for on-line preconcentration and separation of Hg species in water with atomic fluorescence spectrometry detection
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2021-08-25T19:26:57Z
dc.journal.volume
210
dc.journal.pagination
1-8
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Cruz Sotolongo, Annaly. Universidad Nacional de Cuyo. Facultad de Ciencias Exactas y Naturales. Laboratorio de Química Analítica para Investigación y Desarrollo; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto Interdisciplinario de Ciencias Básicas. - Universidad Nacional de Cuyo. Instituto Interdisciplinario de Ciencias Básicas; Argentina
dc.description.fil
Fil: Messina, María Mercedes. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
dc.description.fil
Fil: Ibañez, Francisco Javier. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
dc.description.fil
Fil: Wuilloud, Rodolfo German. Universidad Nacional de Cuyo. Facultad de Ciencias Exactas y Naturales. Laboratorio de Química Analítica para Investigación y Desarrollo; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto Interdisciplinario de Ciencias Básicas. - Universidad Nacional de Cuyo. Instituto Interdisciplinario de Ciencias Básicas; Argentina
dc.journal.title
Talanta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2019.120614
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914019312470?via%3Dihub
Archivos asociados