Artículo
A comparison of failure assessment diagram options for Inconel 690 and Incoloy 800 nuclear steam generators tubes
Fecha de publicación:
01/06/2020
Editorial:
Pergamon-Elsevier Science Ltd
Revista:
Annals of Nuclear Energy
ISSN:
0306-4549
e-ISSN:
1873-2100
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
In the context of structural integrity assessment of cracked Steam Generator Tubes (SGTs), the Failure Assessment Diagram (FAD) has been proposed as a modern tool able to reduce the conservativeness of traditional plastic limit load analyses. As different FAD failure curves are available in the literature, this paper presents a comparison between the so-called Options 1, 2 and 3 FAD curves derived for Inconel 690 and Incoloy 800 nuclear SGTs. Detailed Option 3 curves are obtained from elastoplastic finite element analyses and experimental data from fracture tests. Material-specific Option 2 curves are drawn from stress vs. strain data of uniaxial tests of SGTs. It is shown that the simplest generic Option 1 curve is conservative but appropriate for structural integrity assessments of cracked nuclear SGTs in operation. Alternatively, Option 3 FAD curves must be used when an excessive conservatism shall be avoided.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(CCT - PATAGONIA CONFLUENCIA)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - PATAGONIA CONFLUENCIA
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - PATAGONIA CONFLUENCIA
Citación
Bergant, Marcos Antonio; Yawny, Alejandro Andres; Perez Ipiña, Juan Elias; A comparison of failure assessment diagram options for Inconel 690 and Incoloy 800 nuclear steam generators tubes; Pergamon-Elsevier Science Ltd; Annals of Nuclear Energy; 140; 1-6-2020; 1-10
Compartir
Altmétricas