Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Automatic quantification of cardiomyocyte dimensions and connexin 43 lateralization in fluorescence images

Oliver Gelabert, Antoni; García Mendívil, Laura; Vallejo Gil, José María; Fresneda Roldán, Pedro Carlos; Andelová, Katarína; Fañanás Mastral, Javier; Vázquez Sancho, Manuel; Matamala Adell, Marta; Sorribas Berjón, Fernando; Ballester Cuenca, Carlos; Tribulova, Narcisa; Ordovás, Laura; Diez, Emiliano RaúlIcon ; Pueyo, Esther
Fecha de publicación: 09/2020
Editorial: Molecular Diversity Preservation International
Revista: Biomolecules
ISSN: 2218-273X
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Fisiología

Resumen

Cardiomyocytes’ geometry and connexin 43 (CX43) amount and distribution are structural features that play a pivotal role in electrical conduction. Their quantitative assessment is of high interest in the study of arrhythmias, but it is usually hampered by the lack of automatic tools. In this work, we propose a software algorithm (Myocyte Automatic Retrieval and Tissue Analyzer, MARTA) to automatically detect myocytes from fluorescent microscopy images of cardiac tissue, measure their morphological features and evaluate the expression of CX43 and its degree of lateralization. The proposed software is based on the generation of cell masks, contouring of individual cells, enclosing of cells in minimum area rectangles and splitting of these rectangles into end-to-end and middle compartments to estimate CX43 lateral-to-total ratio. Application to human ventricular tissue images shows that mean differences between automatic and manual methods in terms of cardiomyocyte length and width are below 4 µm. The percentage of lateral CX43 also agrees between automatic and manual evaluation, with the interquartile range approximately covering from 3% to 30% in both cases. MARTA is not limited by fiber orientation and has an optimized speed by using contour filtering, which makes it run hundreds of times faster than a trained expert. Developed for CX43 studies in the left ventricle, MARTA is a flexible tool applicable to morphometric and lateralization studies of other markers in any heart chamber or even skeletal muscle. This open-access software is available online.
Palabras clave: AUTOMATED QUANTIFICATION , CARDIOMYOCYTES , CONNEXIN 43 , FLUORESCENT MICROSCOPY , LATERALIZATION
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 25.78Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/138805
URL: https://www.mdpi.com/2218-273X/10/9/1334
DOI: http://dx.doi.org/10.3390/biom10091334
Colecciones
Articulos(IMBECU)
Articulos de INST. DE MEDICINA Y BIO. EXP. DE CUYO
Citación
Oliver Gelabert, Antoni; García Mendívil, Laura; Vallejo Gil, José María; Fresneda Roldán, Pedro Carlos; Andelová, Katarína; et al.; Automatic quantification of cardiomyocyte dimensions and connexin 43 lateralization in fluorescence images; Molecular Diversity Preservation International; Biomolecules; 10; 9; 9-2020; 1-25
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES